The Crowcon Gasman portable gas detector is an intrinsically safe, compact and lightweight in design piece of gas detection equipment. It is a full function personal single gas monitor which is able to monitor single gases in the most arduous industrial conditions.
Crowcon Gasman is able to detect flammable gas, oxygen and toxic gases in industries such as oil and gas, chemical plants (with exotic gases), steel works (special CO sensor), hospitality (CO2) and waste and water works.
The Gasman single gas detector is user friendly and comfortable to wear, weighing only 130g. Operated by a single button with a large easy to read display and alarms that are both audible (95 dB) and visual (vivid red/ blue LEDs).
Crowcon Gasman is and vibrating option for added safety.
C-Test bump solution, with configuration update, keeps the Crowcon gas detector correctly configured to ensure the product is up-to-date without the need for servicing.
These gas detectors are also water and dust resistant to ingress protection rating IP65. Crowcon Gasman is also available in a safe area CO2 version offering 0-5% carbon dioxide measurement – the Gasman IR CO2.
➡ Also see the range of Crowcon Fixed Gas Detectors.
Crowcon Connect is the only connected safety software that works on new and existing Crowcon portable detectors. Crowcon Connect is developed in-house enabling bespoke solutions for any customer, anywhere.
Crowcon Gasman – Features
- Simple Operation – Crowcon Gasman has a single button operation and an easy to read backlit display for gas readings and diagnostics. It is comfortable to wear and ultra lightweight.
- Robust Construction – The Gasman is manufactured from a tough polycarbonate housing in order to protect the user in even the harshest of environments. It has a full over moulding for high impact resistance and the IP65 rating ensures water and dust resistance.
- Effective Warning – The loud, 945B audible alarm and ultra bright dual red/blue visual alarm ensures the user will be alerted to the presence of gas. There are 2 levels of instantaneous alarm and TWA alarms for toxic versions. Where the ambient noise is high the Gasman can still alert you via an internal vibrating alarm and the high impact blue/red LED alarms.
- Flexible Options – Options are available for flammable gas, oxygen and toxic gases with real time TWA and peak display options. The Gasman detector is available with rechargeable versions for all gas types and non-rechargeable versions for oxygen and toxic gases. The device is also fully interchangeable with intelligent sensor modules.
Sensor Technologies
Next Generation of Sensor Innovations
Reduce cost of ownership without compromise with our new long-life Oxygen sensor
- Industry’s first 5-year warranty
- Lead-free for RoHS compliance
- Reduced sensor replacement
- Lower cost of ownership
- Reduced environmental impact
Accurately detect numerous hazardous gases in one Molecular Property Spectrometer (MPS) sensor for better safety and more operational efficiency.
- First to market single gas personal device
- Significant safety value add
- 5 year sensor warranty
- Hydrogen ready
- True LEL multi-gas accuracy
Crowcon Gasman Bump Testing And Calibration
Routine bump testing is recommended for the range of Crowcon portable gas detectors prior to each use. Bump testing is a brief application of a gas to the sensor to invoke a prescribed reaction, ensuring the gas detector reacts as expected.
Bump testing provides a quick, easy and direct method of verifying gas detectors are performing as required and takes a lot less time than ‘zeroing’ the device.
The bump test is widely accepted as a suitable method of testing gas detection equipment.
Crowcon Gasman Portable Gas Detector
Product Specifications
Size | 90 x 48 x 24 mm (3.5 x 1.9 x 0.95 ins) |
Weight | Flammable 138g (4.9oz) Toxic 118g (4.1oz) Oxygen 129g (4.6oz) Carbon monoxide 139g (4.9oz) |
Typical response times (T90) | Flammable 20s Toxic gas 20s Oxygen 10s |
Alarms | Audible – 95dB Multiple alarm options let you select distinctive tones for different alarm levels; Visible – Dual colours red/ blue flashing LEDs in a gas hazard; Vibrating – Internal vibrating alarm |
Display | Custom LCD with backlight, with display of gas concentration. Graphic symbols for battery (with proportional indication of remaining operation time), and display mode. Start up indication when calibration is due within 30 days, calibration overdue or service required. Normal display: Real time gas concentration levels Display recall: Peak readings and TWA |
Data logging | Full timed data logging with adjustable sample rate, set to 1 min. data rate as default. 900 hours storage at 1 min. interval (54,000 logs), >4800 events |
Battery | Rechargeable – Lithium battery for all gas types; Non rechargeable – Lithium battery for toxics and oxygen (excluding CO₂ ) |
Operating time* | Rechargeable – 12 hours minimum for flammable unit; Non rechargeable – Up to 2 years |
Sampling | Optional manual aspirator |
Operating temperature range** | -20º C to + 65º C (-4º F to +149º F) |
Humidity | 20-90% RH |
Ingress Protection | IP65 |
Hazardous Area Approvals | Europe: Toxic or O2: ATEX II 1G Ex ia IIC T4 Ga (-20°C ≤ Ta ≤ +65°C) BASEEFA04ATEX0384 Flammable: ATEX II 2G Ex ia db IIC T4 Gb (-20°C ≤ Ta ≤ +65°C) BASEEFA04ATEX0383 International: Toxic or O2: IECEx Ex ia IIC T4 Ga (-20°C ≤ Ta ≤ +65°C) BAS05.0039 Flammable: IECEx Ex db ia IIC T4 Gb (-20°C ≤ Ta ≤ +65°C) BAS05.0038 North America: CSA Class 1 Groups A,B,C,D Division 1 |
Standards safety | Europe: EN60079-0, EN60079-11, EN60079-1, ATEX 2014/34/EU North America: CSA22.2, 152EN50270, EN50271, EN61779, EN45544 |
PC interface | RS232 connection from interface module in charger; RS232/USB converter available |
Calibration | Gasman can be routinely calibrated using Portables PC software or by using Checkbox IMH |
Accessories | Gasman is supplied with an integral alligator clip |
Crowcon Connect Compatible? |
Yes |
*Operating time will depend on operating pattern and alarm occurrence. Frequent or long lasting alarms and use of the optional confidence beep will reduce battery life.
**Toxic and oxygen sensors are not rated for continuous operation at high temperatures. Consult Crowcon if operating temperatures are likely to exceed 40ºC (104ºF) for extended periods.
Crowcon Gasman Portable Gas Detector
Gases Detected & Ranges
The Gasman IR CO2 personal single gas monitor has an infrared gas sensor for CO2 detection. This version of the Crowcon Gasman is not designed or certified for use within hazardous areas.
Gas Detection | Range | Standard Alarm |
Ammonia (NH3) | 0-100ppm | 25ppm |
Carbon Monoxide (CO) | 0-500ppm | 30ppm |
Carbon Dioxide (CO2) | 0-5% | 0-5% |
Chlorine (CL2) | 0-20ppm | 0.5ppm |
Flammable Gas | 0-100% LEL | 20% LEL |
Fluorine (F2) | 0-1ppm | 0.1ppm |
Hydrogen (H2) | 0-2000ppm | N/A |
Hydrogen Cyanide (HCN) | 0-25ppm | 5ppm |
Hydrogen Fluoride (HF) | 0-10 ppm | 1ppm |
Hydrogen Sulphide (H2S) | 0-100 ppm | 5ppm |
Nitric Oxide (NO) | 0-100 ppm | 25ppm |
Nitrogen Dioxide (NO2) | 0-20 ppm | 1ppm |
Oxygen (O2) | 0-25% | 19/23% |
Ozone (O3) | 0-1 ppm | 0.1ppm |
Phosphine (PH3) | 0-5 ppm | 0.2ppm |
Phosgene (CCL2) | 0-1 ppm | 0.1ppm |
Sulphur Dioxide (SO2) | 0-20 ppm | 1ppm |
T&D provide competitive prices and delivery for all Crowcon Gas Detectors, including the Crowcon Gasman.
Gas Detection In High Voltage Substations, SWITCHGEAR & Hazardous Area Battery Rooms
See how Crowcon F-Gas Detector is used in the electrical utility industry to provide safe gas detection of SF6 in high voltage substations and gas insulated switchgear.
➡ Did you know? T&D distribute Zone 1 Hazardous Area ATEX Certified Lighting, Heating, Power products – this includes hazardous area portable heaters, LED lighting, plugs and sockets, control panels, enclosures and junction boxes for Zone 1 use.