Ex d Lighting – Explosion Proof Hazardous Area Technor EV HID Wellglass Lighting

Ex d Lighting - Explosion Proof Hazardous Area Technor EV HID Wellglass Lighting

Ex d Lighting – Explosion Proof Hazardous Area Technor EV HID Wellglass Lighting

ZONE 1, ZONE 21 FLUORESCENT LIGHTING

EXPLOSION PROTECTION EX D

Fluorescent Lighting for Zone 1, Zone 21, Zone 2, Zone 22 Hazardous Area Lighting Applications

Thorne & Derrick, the Specialist Distributors of Hazardous Area Lighting can provide competitive prices and supply from stock the complete range of Technor products including electrical enclosures and junction boxes.

Technor’s EV HID is a wellglass Ex d lighting fixture suitable for hazardous area lighting and offers offers Ex-e IIC mode of protection and are suitable for indoor and outdoor hazardous areas of industrial plants where narrow or wide beam lighting is required.

Technor EV HID wellglass lighting is classified to international hazardous area classifications with ATEX, IECEx and TRCU certification, with ingress protection IP66 and an operational ambient temperature range of -52°C to +60°C.

Technor EV HID wellglass lighting fixtures are designed to house built-in control gears for high intensity discharge lamps, mercury vapour, metal halide and high pressure sodium; light source can be driven where required by way of suitable reflectors. The body of the EV HID wellglass is constructed from aluminium with a low content of copper, providing corrosion resistance and a lamp compartment made from tempered glass.

Technor EV HID Wellglass Lighting – Technical Features

MaterialAluminium with low content of copper
IP ratingIP66
Ambient temperature range-52°C to +60°C
ApprovalsINERIS 01ATEX0019X, IECEx INE 15.0031X, CoC TR CU 012/2011 (marking upon request, ordering code to be required)
GasketsO-ring made of Nitrile Rubber (NBR)
Surface treatmentGreen colour polyurethane painting cycle RAL6003 (other colour available upon request)
Entries
N° 2 entries M25x1,5 (EVde and EVCC version) / N° 1 entry M25x1,5 (EVA version) / (plugs and cable glands excluded)
Hardware and screwsAISI304 Stainless steel external hardware and screws
LampsIncluded
BallastElectromechanical ballast
Rated Operation Voltage (UE)230 V (standard) / 220 V, 240 V, 250 V, 277 V (upon request)
Frequency50 Hz (standard) / 60 Hz (upon request)
Accessories available upon requestProtection guard / Reflector / Pole mounting kit (EVde version)
Operating Principles
HOT INSTANT RESTRIKE solution available via twin-arc lamp assuring immediate hot instant restrike ignition with flux that will reach 80% of the nominal lamp flux in about 3 minutes.
HOT INSTANT RESTRIKE solution also available via INSTANT RESTRIKE BALLAST, assuring immediate hot instant restrike ignition with 80% of the lamp nominal flux in 7 seconds. (for high pressure sodium version)

Technor EV HID Lighting – EVde Version

EVde version, with integrated Ex e junction box, allows end users and contractors the possibility to save one junction box, two cable glands and a minimum of 30 minutes of labour during installation process. This version is supplied complete with an adjustable AISI304 stainless steel mounting bracket suitable for ceiling, wall and suspension installation.

(NA) High Pressure Sodium

Technor Part NumberCodeLamp (W)Weight (Kg)Temperature ClassDimensions (mm)Drawing
ABCD
EVDE-2/NA-B 50A041121F0111450**6.00T3*680466214162TAB A-1
EVDE-3/NA-B 50A041131F01114506.00T3*686472214194TAB A-1
EVDE-2/NA-B 70A041121H0111470**6.00T3*680466214162TAB A-1
EVDE-3/NA-B 70A041131H01114707.40T3*686472214194TAB A-1
EVDE-4/NA-B 100A0411411011141007.60T3*748533214220TAB A-1
EVDE-4/NA-B 150A0411411511141508.40T3*748533214220TAB A-1
EVDE-4/NA-B 250A04114125111425015.00T3890676214220TAB A-1
EVDE-5/NA-B 250A04115125111425016.70T3*970756214281TAB A-2
EVDE-5/NA-B 400A04115140111440018.00T3970756214281TAB A-2

* With micro-switch
** In case of maximum ambient temperature reach +60°C, temperature class changes into T4/T135°C (ordering code to be required)
In case of maximum ambient temperature reach +40°C, temperature class changes into T6/T85°C (ordering code to be required)

(HG) Mercury Vapour

Technor Part NumberCodeLamp (W)Weight (Kg)Temperature ClassDimensions (mm)Drawing
ABCD
EVDE-2/HG-B 50A042121F01114506.00T3*680466214162TAB A-1
EVDE-2/HG-B 80A042121I01114806.00T3*680472214194TAB A-1
EVDE-3/HG-B 125A0421311B01131257.40T3686472214194TAB A-1
EVDE-5/HG-B 250A04215125011425015.70T3970756214281TAB A-2
EVDE-5/HG-B 400A04215140011440016.50T3970756214281TAB A-2

*In case of maximum ambient temperature reaches +40°C and except for light/bulb oriented on top (topward), temperature class changes into T4 (ordering code to be required)
Notes:
– Below -20°C, the mercury vapour light can be used, providing they are switched on 24 hours a day
– Mercury vapour light bulb is not included (banned by the European Community)

(IM) Metal Halide

Technor Part NumberCodeLamp (W)Weight (Kg)Temperature ClassDimensions (mm)Drawing
ABCD
EVDE-3/IM-B 70A043131H01114706.00T3*680472214194TAB A-1
EVDE-4/IM-B 100A0431411011141006.00T3*748533214220TAB A-1
EVDE-4/IM-B 150A0431411511141507.40T3*890676214220TAB A-1
EVDE-4/IM-B 250A04314125111425014.80T3890676214220TAB A-2
EVDE-5/IM-B 250A04315125111425015.70T3*890676214220TAB A-2
EVDE-E/IM-B 400A04315140111440016.50T3970756214281TAB A-2

* In case of maximum ambient temperature reaches +40°C and except for light/bulb oriented on top (topward), temperature class changes into T4 (ordering code to be required).
Below -20°c, the metal halide light can be used, providing they are switched on 24 hours a day

Technor EV HID Lighting – EVCC Version

EVCC version, without integrated Ex e junction box, allows standard ceiling installation.

(NA) High Pressure Sodium

Technor Part NumberCodeLamp (W)Weight (Kg)Temperature ClassDimensions (mm)Drawing
AB
EVCC-2/NA-B 50A041221F0111450**5.50T3*406162TAB B
EVCC-3/NA-B 50A041231F01114506.90T3*411194TAB B
EVCC-2/NA-B 70A041221H0111470**5.50T3*406162TAB B
EVCC-3/NA-B 70A041231H01114706.90T3*411194TAB B
EVCC-4/NA-B 100A0412411011141007.10T3*474220TAB B
EVCC-4/NA-B 150A0412411511141507.90T3*474220TAB B

*In case of maximum ambient temperature reaches +55°C and except for light/bulb oriented on top (topward), temperature class changes into T4 (ordering code to be required)
** Lamp with built-in glow discharge ignitor

(HG) Mercury Vapour

Technor Part NumberCodeLamp (W)Weight (Kg)Temperature ClassDimensions (mm)Drawing
AB
EVCC-2/HG-B 50A042221F01114505.50T3*406162TAB B
EVCC-2/HG-B 80A042221I01114805.50T3*406162TAB B
EVCC-3/HG-B 125A0422311B01131256.90T3411194TAB B

*In case of maximum ambient temperature reaches +40°C and except for light/bulb oriented on top (topward), temperature class changes into T4 (ordering code to be required)
Notes:
– Below -20°C, the mercury vapour light can be used, providing they are switched on 24 hours a day
– Mercury vapour light bulb is not included (banned by the European Community)

(IM) Metal Halide

Technor Part NumberCodeLamp (W)Weight (Kg)Temperature ClassDimensions (mm)Drawing
AB
EVCC-3/IM-B 70A043231H01114706.90T3*411194TAB B
EVCC-4/IM-B 100A0432411011141007.10T3*474220TAB B
EVCC-4/IM-B 150A0432411511141507.90T3*474220TAB B

* In case of maximum ambient temperature reaches +40°C and except for light/bulb oriented on top (topward), temperature class changes into T4 (ordering code to be required).
Below -20°c, the metal halide light can be used, providing they are switched on 24 hours a day

Technor EV HID Lighting – EVA Version

EVA version, without integrated Ex e junction box, allows standard suspension installation by conduit system and pastoral pole.

(NA) High Pressure Sodium

Technor Part NumberCodeLamp (W)Weight (Kg)Temperature ClassDimensions (mm)Drawing
AB
EVA-2/NA-B 50A041321F0111450**5.50T3*400162TAB C
EVA-3/NA-B 50A041331F01114506.90T3*404194TAB C
EVA-2/NA-B 70A041321H0111470**5.50T3*400162TAB C
EVA-3/NA-B 70A041331H01114706.90T3*404194TAB C
EVA-4/NA-B 100A0413411011141007.10T3*467220TAB C
EVA-4/NA-B 150A0413411511141507.90T3*467220TAB C

*In case of maximum ambient temperature reaches +55°C and except for light/bulb oriented on top (topward), temperature class changes into T4 (ordering code to be required)
** Lamp with built-in glow discharge ignitor

(HG) Mercury Vapour

Technor Part NumberCodeLamp (W)Weight (Kg)Temperature ClassDimensions (mm)Drawing
AB
EVA-2/HG-B 50A042321F01114505.50T3*400162TAB C
EVA-2/HG-B 80A042321I01114805.50T3*400162TAB C
EVA-3/HG-B 125A0423311B01131256.90T3404194TAB C

*In case of maximum ambient temperature reaches +40°C and except for light/bulb oriented on top (topward), temperature class changes into T4 (ordering code to be required)
Notes:
– Below -20°C, the mercury vapour light can be used, providing they are switched on 24 hours a day
– Mercury vapour light bulb is not included (banned by the European Community)

(IM) Metal Halide

Technor Part NumberCodeLamp (W)Weight (Kg)Temperature ClassDimensions (mm)Drawing
AB
EVA-3/IM-B 70A043331H01114706.90T3*404194TAB C
EVA-4/IM-B 100A0433411011141007.10T3*467220TAB C
EVA-4/IM-B 150A0433411511141507.90T3*467220TAB C

* In case of maximum ambient temperature reaches +40°C and except for light/bulb oriented on top (topward), temperature class changes into T4 (ordering code to be required).
Below -20°c, the metal halide light can be used, providing they are switched on 24 hours a day

Explosion Proof Hazardous Area Technor EV HID Wellglass Lighting - EVde Dimensions

Explosion Proof Hazardous Area Technor EV HID Wellglass Lighting – EVde Dimensions

Explosion Proof Hazardous Area Technor EV HID Wellglass Lighting - EVCC & EVA Dimensions

Explosion Proof Hazardous Area Technor EV HID Wellglass Lighting – EVCC & EVA Dimensions

HAZARDOUS AREA CERTIFICATION & MARKING FOR Lighting

ATEX

  • II 2 GD
  • Ex d IIC T(**) Gb for all EV..
  • Ex de IIC T(**) Gb for all Evde..
  • Ex tb IIIC T(**) Db IP66
  • ** T4/T135 °C ; T3/200°C

IECEx

  • Ex db IIC T(**) Gb
  • Ex db e IIC T(**) Gb
  • Ex tb IIIC T(**) Db IP66

under IEC Ex directive, junction boxes and enclosures are suitable for IIC group of gases/dusts only 

Approvals

Certified 01ATEX0019X, IECEx INE 15.0031X, TR CU (marking upon request, ordering code to be required).