Ex d Lighting – Explosion Proof Hazardous Area Technor EV Wellglass Lighting

Ex d Lighting - Explosion Proof Hazardous Area Technor EV Wellglass Lighting

Ex d Lighting – Explosion Proof Hazardous Area Technor EV Wellglass Lighting

ZONE 1, ZONE 21 Wellglass LIGHTING

EXPLOSION PROTECTION EX D

Fluorescent Lighting for Zone 1, Zone 21, Zone 2, Zone 22 Hazardous Area Lighting Applications

Thorne & Derrick, the Specialist Distributors of Hazardous Area Lighting can provide competitive prices and supply from stock the complete range of Technor products including electrical enclosures and junction boxes.

Technor’s EV is a wellglass Ex d lighting fixture suitable for hazardous area lighting and offers offers Ex-e IIC mode of protection and are suitable for indoor and outdoor hazardous areas of industrial plants where narrow or wide beam lighting is required.

Technor EV wellglass lighting is classified to international hazardous area classifications with ATEX, IECEx and TRCU certification, with ingress protection IP66 and an operational ambient temperature range of -52°C to +60°C.

Technor EV wellglass lighting fixtures are designed to house energy saving lamps; light source can be driven where required by way of suitable reflectors. The body of the EV wellglass is constructed from aluminium with a low content of copper, providing corrosion resistance and a lamp compartment made from tempered glass.

Technor EV Wellglass Lighting – Technical Features

MaterialAluminium with low content of copper
IP ratingIP66
Ambient temperature range-52°C to +60°C
ApprovalsINERIS 01ATEX0019X, IECEx INE 15.0031X, CoC TR CU 012/2011 (marking upon request, ordering code to be required)
GasketsO-ring made of Nitrile Rubber (NBR)
Surface treatmentGreen colour polyurethane painting cycle RAL6003 (other colour available upon request)
Entries
N° 2 entries M25x1,5 (EVde and EVCC version) / N° 1 entry M25x1,5 (EVA version) / (plugs and cable glands excluded)
Hardware and screwsAISI304 Stainless steel external hardware and screws
LampsIncluded
Rated Operation Voltage (UE)
Halogen Lamps
230V (standard)
220V, 240V (upon request)
Fluorescent Lamps
220/240V
Frequency50 Hz (standard) / 60 Hz (upon request)
Accessories available upon requestProtection guard / Reflector / Pole mounting kit (EVde version)

Technor EV Lighting – EVde Version

EVde version, with integrated Ex e junction box, allows end users and contractors the possibility to save one junction box, two cable glands and a minimum of 30 minutes of labour during installation process. This version is supplied complete with an adjustable AISI304 stainless steel mounting bracket suitable for ceiling, wall and suspension installation.

(HA) Halogen – Energy Saving

Technor Part NumberCodeLamp (W)Weight (Kg)Temperature ClassDimensions (mm)
ABCD
EVDE-1/HA 42A044111E2171D42 (Old 60W Inc)2.90T4*505291214146
EVDE-2/HA 42A044121E2171442 (Old 60W Inc)3.10T3**550336214163
EVDE-2/HA 70A044121H0171470 (Old 100W Inc)3.10T3**550336214163
EVDE-2/HA 105A0441211A1714105 (Old 150W Inc)3.10T3**550336214163
EVDE-3/HA 105A0441311A1714105 (Old 150W Inc)4.40T3**584370214194
EVDE-4/HA 140A04414114171D140 (Old 200W Inc)7.00T4635421214220
EVDE-5/HA 200A0441512017142009.00T3***715501214281

*In case of maximum ambient temperature reaches +40°C , temperature class changes into T5 (ordering code to be required)
**In case of maximum ambient temperature reaches +55°C , temperature class changes into T4 (ordering code to be required)
***In case of maximum ambient temperature reaches +40°C , temperature class changes into T4 (ordering code to be required)

(FC) Fluorescent Compact – Energy Saving Long Life (8000H)

Technor Part NumberCodeLamp (W)Weight (Kg)Temperature ClassDimensions (mm)
ABCD
EVDE-2/FC 26A045121C6171D263.10T4*550336214163
EVDE-3/FC 45A045131E5171D45 (Old 200W Inc)4.40T4*584370214194
EVDE-4/FC 45A045141E5171D45 (Old 200W Inc)7.00T4**635421214220
EVDE-5/FC 45A045151E5171D45 (Old 200W Inc)9.00T4**715501214281

*In case of maximum ambient temperature reaches +40°C , temperature class changes into T5 (ordering code to be required)
**In case of maximum ambient temperature reaches +40°C , temperature class changes into T6 (ordering code to be required)
In case of maximum ambient temperature reaches +55°C , temperature class changes into T5 (ordering code to be required)
Notes:
– Below -20°C, the fluorescent compact light can be used, providing they are switched on 24 hours a day

Technor EV HID Lighting – EVCC Version

EVCC version, without integrated Ex e junction box, allows standard ceiling installation.

(HA) Halogen – Energy Saving

Technor Part NumberCodeLamp (W)Weight (Kg)Temperature ClassDimensions (mm)
AB
EVCC-1/HA 42A044211E2171D42 (Old 60W Inc)2.40T4*230146
EVCC-2/HA 42A044221E2171442 (Old 60W Inc)2.60T3**276162
EVCC-2/HA 70A044221H0171470 (Old 100W Inc)2.60T3**276162
EVCC-2/HA 105A0442211A1714105 (Old 150W Inc)2.60T3**276162
EVCC-3/HA 105A0442311A1714105 (Old 150W Inc)3.90T3**309194
EVCC-4/HA 140A04424114171D140 (Old 200W Inc)6.50T4360220
EVCC-5/HA 200A0442512017142008.50T3***440281

*In case of maximum ambient temperature reaches +40°C , temperature class changes into T5 (ordering code to be required)
**In case of maximum ambient temperature reaches +55°C , temperature class changes into T4 (ordering code to be required)
***In case of maximum ambient temperature reaches +40°C , temperature class changes into T4 (ordering code to be required)

(FC) Fluorescent Compact – Energy Saving Long Life (8000H)

Technor Part NumberCodeLamp (W)Weight (Kg)Temperature ClassDimensions (mm)
AB
EVCC-2/FC 26A045221C6171D262.60T4*276162
EVCC-3/FC 45A045231E5171D45 (Old 200W Inc)3.90T4*309194
EVCC-4/FC 45A045241E5171D45 (Old 200W Inc)6.50T4**360220
EVCC-5/FC 45A045251E5171D45 (Old 200W Inc)8.50T4**440281

*In case of maximum ambient temperature reaches +40°C , temperature class changes into T5 (ordering code to be required)
**In case of maximum ambient temperature reaches +40°C , temperature class changes into T6 (ordering code to be required)
In case of maximum ambient temperature reaches +55°C , temperature class changes into T5 (ordering code to be required)
Notes:
– Below -20°C, the fluorescent compact light can be used, providing they are switched on 24 hours a day

Technor EV HID Lighting – EVA Version

EVA version, without integrated Ex e junction box, allows standard suspension installation by conduit system and pastoral pole.

(HA) Halogen – Energy Saving

Technor Part NumberCodeLamp (W)Weight (Kg)Temperature ClassDimensions (mm)
AB
EVA-1/HA 42A044311E2171D42 (Old 60W Inc)2.40T4*230146
EVA-2/HA 42A044321E2171442 (Old 60W Inc)2.60T3**276162
EVA-2/HA 70A044321H0171470 (Old 100W Inc)2.60T3**276162
EVA-2/HA 105A0443211A1714105 (Old 150W Inc)2.60T3**276162
EVA-3/HA 105A0443311A1714105 (Old 150W Inc)3.90T3**309194
EVA-4/HA 140A04434114171D140 (Old 200W Inc)6.50T4360220
EVA-5/HA 200A0443512017142008.50T3***440281

*In case of maximum ambient temperature reaches +40°C , temperature class changes into T5 (ordering code to be required)
**In case of maximum ambient temperature reaches +55°C , temperature class changes into T4 (ordering code to be required)
***In case of maximum ambient temperature reaches +40°C , temperature class changes into T4 (ordering code to be required)

(FC) Fluorescent Compact – Energy Saving Long Life (8000H)

Technor Part NumberCodeLamp (W)Weight (Kg)Temperature ClassDimensions (mm)
AB
EVA-2/FC 26A045321C6171D262.60T4*276162
EVA-3/FC 45A045331E5171D45 (Old 200W Inc)3.90T4*309194
EVA-4/FC 45A045341E5171D45 (Old 200W Inc)6.50T4**360220
EVA-5/FC 45A045351E5171D45 (Old 200W Inc)8.50T4**440281

*In case of maximum ambient temperature reaches +40°C , temperature class changes into T5 (ordering code to be required)
**In case of maximum ambient temperature reaches +40°C , temperature class changes into T6 (ordering code to be required)
In case of maximum ambient temperature reaches +55°C , temperature class changes into T5 (ordering code to be required)
Notes:
– Below -20°C, the fluorescent compact light can be used, providing they are switched on 24 hours a day

Explosion Proof Hazardous Area Technor EV Wellglass Lighting - EVde Dimensions

Explosion Proof Hazardous Area Technor EV Wellglass Lighting – EVde Dimensions

Explosion Proof Hazardous Area Technor EV Wellglass Lighting - EVCC Dimensions

Explosion Proof Hazardous Area Technor EV Wellglass Lighting – EVCC Dimensions

Explosion Proof Hazardous Area Technor EV Wellglass Lighting - EVA Dimensions

Explosion Proof Hazardous Area Technor EV Wellglass Lighting – EVA Dimensions

HAZARDOUS AREA CERTIFICATION & MARKING FOR Lighting

II 2 GD

  • Ex d IIC T(**) Gb for all EV..
  • Ex de IIC T(**) Gb for all EVde..
  • Ex tb IIIC T(**) Db IP66
  • ** T5/T100°C, T4/T135°C, T3/200°C

under IEC Ex directive, junction boxes and enclosures are suitable for IIC group of gases/dusts only 

Approvals

Certified 01ATEX0019X (standard), IECEx INE 15.0031X, CoC TR CU 012/2011 (marking upon request, ordering code to be required)