Ex d Lighting – Explosion Proof Hazardous Area Technor EV Wellglass Lighting

Ex d Lighting - Explosion Proof Hazardous Area Technor EV Wellglass Lighting

Ex d Lighting – Explosion Proof Hazardous Area Technor EV Wellglass Lighting

ZONE 1, ZONE 21 Wellglass LIGHTING

EXPLOSION PROTECTION EX D

Fluorescent Lighting for Zone 1, Zone 21, Zone 2, Zone 22 Hazardous Area Lighting Applications

Thorne & Derrick, the Specialist Distributors of Hazardous Area Lighting can provide competitive prices and supply from stock the complete range of Technor products including electrical enclosures and junction boxes.

Technor’s EV is a wellglass Ex d lighting fixture suitable for hazardous area lighting and offers offers Ex-e IIC mode of protection and are suitable for indoor and outdoor hazardous areas of industrial plants where narrow or wide beam lighting is required.

Technor EV wellglass lighting is classified to international hazardous area classifications with ATEX, IECEx and TRCU certification, with ingress protection IP66 and an operational ambient temperature range of -52°C to +60°C.

Technor EV wellglass lighting fixtures are designed to house energy saving lamps; light source can be driven where required by way of suitable reflectors. The body of the EV wellglass is constructed from aluminium with a low content of copper, providing corrosion resistance and a lamp compartment made from tempered glass.

Technor EV Wellglass Lighting – Technical Features

Material Aluminium with low content of copper
IP rating IP66
Ambient temperature range -52°C to +60°C
Approvals INERIS 01ATEX0019X, IECEx INE 15.0031X, CoC TR CU 012/2011 (marking upon request, ordering code to be required)
Gaskets O-ring made of Nitrile Rubber (NBR)
Surface treatment Green colour polyurethane painting cycle RAL6003 (other colour available upon request)
Entries
N° 2 entries M25x1,5 (EVde and EVCC version) / N° 1 entry M25x1,5 (EVA version) / (plugs and cable glands excluded)
Hardware and screws AISI304 Stainless steel external hardware and screws
Lamps Included
Rated Operation Voltage (UE)
Halogen Lamps
230V (standard)
220V, 240V (upon request)
Fluorescent Lamps
220/240V
Frequency 50 Hz (standard) / 60 Hz (upon request)
Accessories available upon request Protection guard / Reflector / Pole mounting kit (EVde version)

Technor EV Lighting – EVde Version

EVde version, with integrated Ex e junction box, allows end users and contractors the possibility to save one junction box, two cable glands and a minimum of 30 minutes of labour during installation process. This version is supplied complete with an adjustable AISI304 stainless steel mounting bracket suitable for ceiling, wall and suspension installation.

(HA) Halogen – Energy Saving

Technor Part Number Code Lamp (W) Weight (Kg) Temperature Class Dimensions (mm)
A B C D
EVDE-1/HA 42 A044111E2171D 42 (Old 60W Inc) 2.90 T4* 505 291 214 146
EVDE-2/HA 42 A044121E21714 42 (Old 60W Inc) 3.10 T3** 550 336 214 163
EVDE-2/HA 70 A044121H01714 70 (Old 100W Inc) 3.10 T3** 550 336 214 163
EVDE-2/HA 105 A0441211A1714 105 (Old 150W Inc) 3.10 T3** 550 336 214 163
EVDE-3/HA 105 A0441311A1714 105 (Old 150W Inc) 4.40 T3** 584 370 214 194
EVDE-4/HA 140 A04414114171D 140 (Old 200W Inc) 7.00 T4 635 421 214 220
EVDE-5/HA 200 A044151201714 200 9.00 T3*** 715 501 214 281

*In case of maximum ambient temperature reaches +40°C , temperature class changes into T5 (ordering code to be required)
**In case of maximum ambient temperature reaches +55°C , temperature class changes into T4 (ordering code to be required)
***In case of maximum ambient temperature reaches +40°C , temperature class changes into T4 (ordering code to be required)

(FC) Fluorescent Compact – Energy Saving Long Life (8000H)

Technor Part Number Code Lamp (W) Weight (Kg) Temperature Class Dimensions (mm)
A B C D
EVDE-2/FC 26 A045121C6171D 26 3.10 T4* 550 336 214 163
EVDE-3/FC 45 A045131E5171D 45 (Old 200W Inc) 4.40 T4* 584 370 214 194
EVDE-4/FC 45 A045141E5171D 45 (Old 200W Inc) 7.00 T4** 635 421 214 220
EVDE-5/FC 45 A045151E5171D 45 (Old 200W Inc) 9.00 T4** 715 501 214 281

*In case of maximum ambient temperature reaches +40°C , temperature class changes into T5 (ordering code to be required)
**In case of maximum ambient temperature reaches +40°C , temperature class changes into T6 (ordering code to be required)
In case of maximum ambient temperature reaches +55°C , temperature class changes into T5 (ordering code to be required)
Notes:
– Below -20°C, the fluorescent compact light can be used, providing they are switched on 24 hours a day

Technor EV HID Lighting – EVCC Version

EVCC version, without integrated Ex e junction box, allows standard ceiling installation.

(HA) Halogen – Energy Saving

Technor Part Number Code Lamp (W) Weight (Kg) Temperature Class Dimensions (mm)
A B
EVCC-1/HA 42 A044211E2171D 42 (Old 60W Inc) 2.40 T4* 230 146
EVCC-2/HA 42 A044221E21714 42 (Old 60W Inc) 2.60 T3** 276 162
EVCC-2/HA 70 A044221H01714 70 (Old 100W Inc) 2.60 T3** 276 162
EVCC-2/HA 105 A0442211A1714 105 (Old 150W Inc) 2.60 T3** 276 162
EVCC-3/HA 105 A0442311A1714 105 (Old 150W Inc) 3.90 T3** 309 194
EVCC-4/HA 140 A04424114171D 140 (Old 200W Inc) 6.50 T4 360 220
EVCC-5/HA 200 A044251201714 200 8.50 T3*** 440 281

*In case of maximum ambient temperature reaches +40°C , temperature class changes into T5 (ordering code to be required)
**In case of maximum ambient temperature reaches +55°C , temperature class changes into T4 (ordering code to be required)
***In case of maximum ambient temperature reaches +40°C , temperature class changes into T4 (ordering code to be required)

(FC) Fluorescent Compact – Energy Saving Long Life (8000H)

Technor Part Number Code Lamp (W) Weight (Kg) Temperature Class Dimensions (mm)
A B
EVCC-2/FC 26 A045221C6171D 26 2.60 T4* 276 162
EVCC-3/FC 45 A045231E5171D 45 (Old 200W Inc) 3.90 T4* 309 194
EVCC-4/FC 45 A045241E5171D 45 (Old 200W Inc) 6.50 T4** 360 220
EVCC-5/FC 45 A045251E5171D 45 (Old 200W Inc) 8.50 T4** 440 281

*In case of maximum ambient temperature reaches +40°C , temperature class changes into T5 (ordering code to be required)
**In case of maximum ambient temperature reaches +40°C , temperature class changes into T6 (ordering code to be required)
In case of maximum ambient temperature reaches +55°C , temperature class changes into T5 (ordering code to be required)
Notes:
– Below -20°C, the fluorescent compact light can be used, providing they are switched on 24 hours a day

Technor EV HID Lighting – EVA Version

EVA version, without integrated Ex e junction box, allows standard suspension installation by conduit system and pastoral pole.

(HA) Halogen – Energy Saving

Technor Part Number Code Lamp (W) Weight (Kg) Temperature Class Dimensions (mm)
A B
EVA-1/HA 42 A044311E2171D 42 (Old 60W Inc) 2.40 T4* 230 146
EVA-2/HA 42 A044321E21714 42 (Old 60W Inc) 2.60 T3** 276 162
EVA-2/HA 70 A044321H01714 70 (Old 100W Inc) 2.60 T3** 276 162
EVA-2/HA 105 A0443211A1714 105 (Old 150W Inc) 2.60 T3** 276 162
EVA-3/HA 105 A0443311A1714 105 (Old 150W Inc) 3.90 T3** 309 194
EVA-4/HA 140 A04434114171D 140 (Old 200W Inc) 6.50 T4 360 220
EVA-5/HA 200 A044351201714 200 8.50 T3*** 440 281

*In case of maximum ambient temperature reaches +40°C , temperature class changes into T5 (ordering code to be required)
**In case of maximum ambient temperature reaches +55°C , temperature class changes into T4 (ordering code to be required)
***In case of maximum ambient temperature reaches +40°C , temperature class changes into T4 (ordering code to be required)

(FC) Fluorescent Compact – Energy Saving Long Life (8000H)

Technor Part Number Code Lamp (W) Weight (Kg) Temperature Class Dimensions (mm)
A B
EVA-2/FC 26 A045321C6171D 26 2.60 T4* 276 162
EVA-3/FC 45 A045331E5171D 45 (Old 200W Inc) 3.90 T4* 309 194
EVA-4/FC 45 A045341E5171D 45 (Old 200W Inc) 6.50 T4** 360 220
EVA-5/FC 45 A045351E5171D 45 (Old 200W Inc) 8.50 T4** 440 281

*In case of maximum ambient temperature reaches +40°C , temperature class changes into T5 (ordering code to be required)
**In case of maximum ambient temperature reaches +40°C , temperature class changes into T6 (ordering code to be required)
In case of maximum ambient temperature reaches +55°C , temperature class changes into T5 (ordering code to be required)
Notes:
– Below -20°C, the fluorescent compact light can be used, providing they are switched on 24 hours a day

Explosion Proof Hazardous Area Technor EV Wellglass Lighting - EVde Dimensions

Explosion Proof Hazardous Area Technor EV Wellglass Lighting – EVde Dimensions

Explosion Proof Hazardous Area Technor EV Wellglass Lighting - EVCC Dimensions

Explosion Proof Hazardous Area Technor EV Wellglass Lighting – EVCC Dimensions

Explosion Proof Hazardous Area Technor EV Wellglass Lighting - EVA Dimensions

Explosion Proof Hazardous Area Technor EV Wellglass Lighting – EVA Dimensions

HAZARDOUS AREA CERTIFICATION & MARKING FOR Lighting

II 2 GD

  • Ex d IIC T(**) Gb for all EV..
  • Ex de IIC T(**) Gb for all EVde..
  • Ex tb IIIC T(**) Db IP66
  • ** T5/T100°C, T4/T135°C, T3/200°C

under IEC Ex directive, junction boxes and enclosures are suitable for IIC group of gases/dusts only 

Approvals

Certified 01ATEX0019X (standard), IECEx INE 15.0031X, CoC TR CU 012/2011 (marking upon request, ordering code to be required)

Data Sheets