Trace Heating Cables | Chromalox

View Sub Products

Chromalox Trace Heating Cables

Chromalox Cables – Heat Trace. Industrial & Hazardous Area Zone 1 Zone 2 ATEX

Trace Heating Cables

Chromalox cables provide trace heating to commercial, industrial and hazardous area location pipework, tanks, vessels and drums – ATEX certified heating cables are available for installation to process pipework requiring temperature maintenance in Zone 1 & Zone 2 hazardous areas with potentially explosive atmospheres (according to ATEX Directive).

Chromalox Cables

Contact Thorne & Derrick International to discuss your heat tracing cable and system requirements – we are Approved Distributors for Chromalox and can provide full trace heating system design and heat loss calculations for both frost protection and temperature maintenance heating applications in commercial, industrial and hazardous area locations in the explosive atmosphere industries.

We guarantee excellent customer service and fast delivery of Chromalox cables from extensive stocks at the most competitive prices.

➡ The following table provides an overview of the range of heating cables for tracing pipework and mechanical services manufactured by Chromalox:

Chromalox Heat Trace CablesCable SizeWatts Per FootCable VoltageProcess Temperature MaintenanceHazardous Area CertificationsHeating Cable Circuit Length Cable
SRL Self Regulating Trace Heating Cable3/8″ Width x 1/8″ Height3, 5, 8 and 10120V and 208-277VUp to 150° F (65° Celsius)ATEX CSA FM GOST IECEx UL660 FeetChromalox SRL Self Regulating Trace Heating Cable
SRP Self Regulating Trace Heating Cable3/8″ Width x 1/8″ Height5, 10 and 15120V and 208-277VUp to 275ºF (135º Celsius)ATEX CSA FM UL750 FeetChromalox SRP Self Regulating Trace Heating Cable
SRM/E Self Regulating Trace Heating Cable3/8″ Width x 1/8″ Height3, 5, 8, 10, 15 and 20120V and 208-277VUp to 420ºF (215º Celsius) ATEX IECEx CSA FM UL750 FeetChromalox SRME Self Regulating Trace Heating Cable
CWM Trace Constant Wattage Heating Cable3/8″ Width x 1/8″ Height4, 8 and 12120V, 208-277V and 480VUp to 392ºF (200º Celsius)CSA UL780 FeetChromalox CWM Constant Wattage Trace Heating Cable
SRF-RG Self Regulating Trace Heating Cable3/8″ Width x 1/8″ Height12120V and 208-277VUp to 150° F (65° Celsius)CSA UL540 FeetChromalox SRF Roof & Gutter Heating Trace Heating Cable
HSRL Self Regulating Trace Heating Cable3/8″ Width x 1/8″ Height3, 5, 8 and 10120V and 208-277VUp to 150° F (65° Celsius)CSA FM660 FeetChromalox HSRL Heat Tracing Cables
HSRM Self Regulating Trace Heating Cable3/8″ Width x 1/8″ Height5, 8, 10, 15 and 20120V and 208-277VUp to 420ºF (215º Celsius)CSA FM750 FeetChromalox HSRM Heat Tracing Cables
MI Mineral Insulated Heating Cable3/16″ to 5/16″Up to 80120V – 600VUp to 1100ºF (593º Celsius)CSA FM500 FeetHeating Cables | MI Mineral Insulated Heat Tracing Cables
HWM Hot Water Maintenance Cable3/8″ Width x 1/8″ Height5 and 10120V and 208-277VUp to 140ºF (60º Celsius)N/A800 FeetHeating Cables | Chromalox HWM Hot Water Trace Heating Cables
SLL Long Line Trace Heating Cable3/8″ Width x 1/8″ HeightUp to 12120V – 600VUp to 450ºF (232º Celsius)N/A7,500 FeetHeating Cables | Chromalox SLL Trace Heating Cables
SRF Self Regulating Trace Heating Cable3/8″ Width x 1/8″ Height3, 5 and 8120V and 208-277VUp to 185ºF (85º Celsius)CSA, UL660 FeetHeating Cables | Chromalox SRF Trace Heating Cables Frost Protection

Chromalox Trace Heating Cables

A video overview of Chromalox trace heating cables and products – T&D can provide training and advice of the installation Chromalox cables.

Chromalox

Chromalox technical manual documenting heating cable selection, design, heat loss calculations and heat transfer fundamentals and radiant infrared heating theory. Should you require any technical support please do not hesitate to contact T&D.

Heat Tracing Cables

Heat tracing is the process of applying electrical heat to provide process temperature maintenance of pipes (containing viscous fluids prone to hardening, congealing or gelling). The heating cable can be linearly or helically installed on the external surface of the pipework and then thermal insulation or lagging is fitted over the heat trace cable to reduce heat losses.

Similarly, heating cables can be used to provide frost protection to water pipework at risk of freezing during winter – furthermore roof/gutter heating and ramp heating systems can be specified to prevent snow and ice build-up and formation.

➡ For complete information about Chromalox Cables please refer to the product sections below – heat trace cables in self-regulating, constant wattage or mineral insulated (MI) technology are available to suit all types of pipework (plastic, metallic, stainless steel), workplace location (non-hazardous or hazardous area) and process temperature heating up to 593° Celsius.

Heating Cables | Self-Regulating | MI Mineral Insulated | Constant Wattage

Heating Cables | Self-Regulating | MI Mineral Insulated | Constant Wattage