💡 Should you require technical support to enable the specification of energy-saving high performance doors to ensure Compliance with the ATEX Directive for safe use in explosive atmospheres and hazardous area locations please do not hesitate to contact us.
You can Follow our Showcase Page on LinkedIn to receive updates about more hazardous area product innovations, industry news, whitepapers, videos, technical tips and training webinars for professionals involved in the explosive atmosphere industries.
Experts In Equipment for Explosive Atmospheres | Leaders in ATEX Innovation
Specifying Doors for Energy Savings & Maximum Safety in Explosive Atmospheres
uploaded by Chris Dodds | Sales & Marketing Manager with Thorne & Derrick International
Welcome to our online Tutorial hosted by Yves Degroote from Dynaco, the leading manufacturer of high performance, high speed doors for industrial, hazardous areas and explosive atmosphere applications.
Yves provides an excellent technical and terminological explanation of the ATEX Directive and the commercial features and benefits of their Dynaco S-5 market leading ATEX certified door. The origins of ATEX is covered and the Directive’s role in accident and incident prevention in the oil, gas and chemicals industries.
The intention of this Tutorial is to raise industry awareness of potential non-compliance risks in the hazardous area industries – we present an innovative and ATEX compliant solutionwhich when carefully understood can actually deliver proven economic benefits through reduced energy costsand improved worksite productivity with carbon footprint reductions and Health & Safety improvements.
ATEX Doors for Hazardous Areas
Tutorial Overview. Run Time 31.15.
What is ATEX & Hazardous Area Classification – Why? Where? How? Who? When?
Worst Situation Scenario’s – Video & Accident History
ATEX Certification – Summary
ATEX Zones – What is the Level of Explosion Risk for Flammable Hazardous Gas & Vapour
ATEX Zones – What is the Level of Explosion Risk for Combustible Ducts
Explosive Gas and Dust Groups & Temperature Class Ratings (T-Class)
Demonstrating Cost Justification Through ROI To End Clients
Partioning In Hazardous Area Zones & Reducing Footprint Costs of ATEX Classified Zones
How & Why To Specify High Speed Doors To Ensure Compliance with ATEX 2014/34/EU
Energy Savings
Ask us to calculate your temperature losses + confirm the expected annual energy savings by installing high speed doors. Should you be interested to receive a FREE ROI REPORTto assess the energy efficiency impact Dynaco doors could have on your facility contact us.
More Benefits
Market Leading ATEX Doors | Compliant & Certified
ATEX DOORS
High Speed Roll-up Doors for Hazardous Areas & Explosive Atmospheres
Thorne and Derrick are the Exclusive UK Distribution Partner for Dynaco ATEX Doors for Hazardous Areas – this range of doors, certified according to the ATEX Directive, are high speed and roll-up design. The doors provide a unique safety solution for clients who need to maintain or improve workflow in hazardous area locations and explosive atmospheres.
To enable the safe storage, transportation, heating and handling of flammable liquids contained in IBC containers and drums we stock a complete range of heating jackets and drum handling equipment certified according to the ATEX Directive.
EXPERTS IN EQUIPMENT FOR EXPLOSIVE ATMOSPHERES
leaders in ATEX Innovation To The Hazardous Area Industries
Thorne & Derrick are leaders in the development and distribution of Product Innovations that deliver significant improvements to clients plant, people and operational safety in the explosive atmosphere industries.
Your proactive problem solvers experienced in succession planning for the replacement of obsolete, non-conformant and legacy equipment in hazardous areas.
Your first-choice provider of innovative and competitive solutions to ensure ATEX & IECEx Compliance for Hazardous Area Electrical, HVAC & Process Instrumentation Equipment to UK and international projects.
ATEX doors for explosive atmospheres and hazardous areas
ATEX Doors: High-Speed Roll-Up Doors for Hazardous Areas
High-speed doors can help separate working areas, manage access and protect industrial environments from external conditions. Where a facility contains a potentially explosive atmosphere, the door and its associated equipment must suit the site’s hazardous area classification.
Evonik Nutrition & Care GmbH produces speciality chemicals for a range of industries. The company approached Entrematic in Belgium to find a door solution for a facility where potentially explosive atmospheres required careful consideration.
The installation needed to help protect the internal working environment from direct sunlight and external weather while allowing forklifts to move easily between the storage area and the wider facility.
Entrematic Belgium worked with a local distributor to install a Dynaco S-549 high-speed ATEX door. The door provided access to stored active ingredients within a classified hazardous area.
Project Requirements
Provide convenient forklift access to the storage area.
Help protect stored products from direct sunlight and adverse weather.
Support frequent movement through the doorway.
Allow the door curtain to reinsert automatically following an impact, as described in the original case study.
Meet the requirements of the site’s hazardous area classification.
Installed Solution: Dynaco S-549
Entrematic Belgium supplied a Dynaco S-549 door measuring 5,500 × 3,700 mm. The original case study identifies this installation as a Category 2, Zone 2 ATEX door. Confirm the installed unit’s exact certification and configuration against the project documentation before using this case study as a specification reference.
Dynaco S-549 high-speed roll-up door
Benefits of High-Speed ATEX Doors
Improve Energy Efficiency
High-speed doors can reduce the time a doorway remains open, helping limit heat transfer between areas. The potential energy savings depend on factors such as the building layout, door dimensions, traffic frequency, temperature difference and existing heating or cooling systems.
Reducing heat loss may also help building designers assess heating requirements for new facilities. Any reduction in heater capacity or operating costs should be calculated for the specific building and operating conditions.
Dynaco ATEX Door Range: Product Overview
The Dynaco range includes high-speed roll-up door models for selected indoor and outdoor applications. The models listed below cover different hazardous area zones and installation requirements.
Use this overview as an initial guide. Visit the relevant product page and check the current manufacturer’s documentation for full specifications, certification, dimensions and installation conditions.
Zone 1 & 21: All-weather door
Zone 1 & 21: Power door
Zone 1 & 21: Compact door
Dynaco S-559
Designed for outdoor use. The original product information states wind resistance up to class 5.
Dynaco S-549
Designed for outdoor use. The original product information states wind resistance up to class 4.
Dynaco S-539
Designed for indoor hazardous area applications.
Ex II 2 G/D
Ex h T4 135°C
Ex db ia e IIC T4 EPL Gb
Ex tb ia IIIB 135°C EPL Db
Ex II 2 G/D
Ex h T4 135°C
Ex db ia e IIC T4 EPL Gb
Ex tb ia IIIB 135°C EPL Db
CE 0029; APRAGAZ 17 ATEX 0157 X
Ex II 2 G/D
Ex h T4 135°C
Ex db ia e IIC T4 EPL Gb
Ex tb ia IIIB 135°C EPL Db
CE 0029; APRAGAZ 17 ATEX 0157 X
Zone 2 & 22: All-weather door
Zone 2 & 22: Power door
Zone 2 & 22: Compact door
Dynaco S-555
Designed for outdoor use. The original product information states wind resistance up to class 5.
Dynaco S-545
Designed for outdoor use. The original product information states wind resistance up to class 4.
Dynaco S-535
Designed for indoor hazardous area applications.
Ex II 3 G/D
Ex h IIC T6 EPL Gb
Ex h IIIC 85°C EPL Db
Ex db mc ia e IIC T4 EPL Gc
Ex tb mc tD IIIB 135°C EPL Dc
CE 0029; APRAGAZ 16ATEX 0150X/1
Ex II 3 G/D
Ex h IIC T6 EPL Gb
Ex h IIIC 85°C EPL Db
Ex db mc ia e IIC T4 EPL Gc
Ex tb mc tD IIIB 135°C EPL Dc
CE 0029; APRAGAZ 16ATEX 0150X/1
Ex II 3 G/D
Ex h IIC T6 EPL Gb
Ex h IIIC 85°C EPL Db
Ex db mc ia e IIC T4 EPL Gc
Ex tb mc tD IIIB 135°C EPL Dc
CE 0029; APRAGAZ 16ATEX 0150X/1
Certification note: The model descriptions and certification markings above come from the original page content. Verify them against the current certificates and technical datasheets before relying on them for equipment selection or compliance decisions.
Discuss Your ATEX Door Requirements
Choosing a high-speed door for a hazardous area involves more than selecting the opening dimensions. Consider the area’s classification, indoor or outdoor installation, traffic levels, environmental conditions and the required protection for the complete door system.
Thorne & Derrick supplies electrical, HVAC and process instrumentation equipment for hazardous area applications. We support customers sourcing equipment for new projects and replacing legacy products, with attention to the technical requirements of each installation.
Press release date: 2 April 2020 | Originally uploaded by Chris Dodds, T&D Sales & Marketing Manager Dynaco ATEX Doors: Certified High-Speed Doors for Hazardous Areas Thorne & Derrick International announced an exclusive UK distribution agreement with Dynaco in...
Press Release Date: 04.07.2019 uploaded by Chris Dodds (T&D Sales + Marketing Manager) Category: Stockist Distributor Agreement Announcement Thorne & Derrick International announce that they have signed a Preferred Distributor Agreement with Raytec, the world leading manufacturer of LED...