Thorne & Derrick International, based in the UK, are the leading supplier of ATEX Lighting for safe and reliable installation in hazardous areas and locations – this includes Lighting for hazardous areas certified by the ATEX Directive for use in Zone 1 and Zone 2 potentially explosive atmospheres in both onshore and offshore locations Zone 1 & 2 Flammable Gas and Zone 21 & 22 (Combustible Dust).
We are Main Distributors for Raytec – this includes ATEX Lighting product groups: Floodlights, Linear Light Fittings, Bulkheads & High Bay.
A complete range of portable lighting for temporary applications with ATEX and IECEx Certification is available – the Wolf Safety Safety Lamp Company provide safe lighting products for use in potentially explosive atmospheres where the presence of flammable gas, vapour or dusts pose a potential explosion risk.
Lighting products are available for Zone 0, Zone 1 (21) and Zone 2 (22) hazardous area classifications according to the ATEX Directive.
Lighting
Hazardous area lighting for safe use in potentially explosive atmospheres, including Zones 1 / 2 (gases) and Zones 21 / 22 (dusts) certified to ATEX and IECEx.
Fluorescent or LED – Emergency, Bulkhead, Well Glass & Floodlights
Temporary Floodlights, Tanklights, Airlamps & Mobile Lighting
Hazardous Area ATEX | Portable & Temporary Lighting | Wolf Safety Lamp Stockist
The SPARTAN range of lighting manufactured by Raytec is designed for lighting hazardous areas which require high performance, high reliability, White-Light illumination using LED technology – ATEX Certified Zone 1 & Zone 2.
What Is ATEX?
ATEX is “ATmosphere EXplosible”
ATEX is the name commonly given to the two European Directives for controlling explosive atmospheres: 1) Directive 99/92/EC (also known as ‘ATEX 137’ or the ‘ATEX Workplace Directive’) on minimum requirements for improving the health and safety protection of workers potentially at risk from explosive atmospheres working in hazardous area industries. The ATEX Zones for lighting products are designated either Zone 1 or Zone 2 depending on the exposure threat to flammable gases or vapours – accordingly these hazardous area lighting systems must be correctly specified according to the level of explosion. Classifying hazardous areas into Zones:
Zone 1 v Zone 2
Hazardous Areas
Zone 1: is a hazardous area classified by ATEX in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is likely to occur in normal operation occasionally.
Zone 2: is a hazardous area classified by ATEX in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is not likely to occur in normal operation but, if it does occur, persists for a short period only.
Hazardous areas are classified in terms of zones on the basis of the frequency and duration of the occurrence of an explosive atmosphere.
Hazardous Area Floodlights
SPARTAN Floodlights have been specified and installed to provide lighting to hazardous area locations and workspaces on an offshore Jack-up drilling rig which had been brought in for maintenance in the Middle East. General illumination of this rig, including ATEX floodlights and lighting for access areas and walkways, was a necessity for the safety and efficiency of the workers. All SPARTAN emergency lighting products, manufactured by Raytec, installed provided 100% light output for 1 hour with both IECEx and ATEX Certification.
How Can We Help?
The following video provides an excellent presentation of the Raytec SPARTAN range of Hazardous Area LED Lighting Products for Zone 1 & Zone 2 (ATEX) – high lumen output is provided by the latest high performance LED technology delivering low running costs and low energy consumption. The modular design hazardous area ATEX lighting system is specified to provide ease of maintenance and inspection with spare part availability for quick repair and replacement of light fixtures and fittings.
T&D are stockists and suppliers of an extensive range of Hazardous Area Electrical Equipment – this includes explosion proof (Ex e) and flameproof (Ex d) products certified by ATEX for use in hazardous areas and explosive atmospheres:
➡ Our Lighting Sales Team are trained and manufactured approved to provide technical support and lighting specification services covering Hazardous Area Zone or Category, Type of Explosion Protection, Gas Group, Temperature Class (T Class Rating) and Equipment Protection Level concepts.
Lighting Designs For Hazardous Areas
Upgrading Plant Legacy Lighting to LED
Thorne & Derrick International, based in the UK, are leading Stockists & Distributors of hazardous area lighting products utilising conventional light fittings and more powerful modern technology White-Light illumination using LED technology – from stock we provide competitive prices and technical support to enable the specification of explosive atmosphere lighting schemes compliant and certified to international standards including ATEX and IECEx.
Using latest software our FREE Lighting Design Service supports the upgrade from fluorescent to LED lighting focussed on maximised light output, optimised energy consumption with reliable and safe certification for explosion protection concepts in Zone 1 and Zone 2 hazardous area zones and workplaces.
Marechal hazardous area plugs and sockets offer an extensive and comprehensive product range for all industrial electrical power applications in Zone 1 & Zone 2 Hazardous Areas with power currents varying from 10A to 680A with up to 1,500 volt power supplies – ATEX certified plugs and sockets.
Typical applications for explosion-proof hazardous area plugs include mobile machinery, portable plant, wellhead control panels, mobile skid units and offshore heavy power, data and signal distribution.
ATEX Plugs & Sockets
Hazardous Areas
Thorne & Derrick are Approved Main Distributors for Marechal Hazardous Area Plugs – contact us for competitive prices, fast delivery and expert technical support to enable the selection and specification of the correct plug, socket or decontactor for all industrial and hazardous area power distribution applications.
A Decontactor® is a plug and socket outlet system with an integrated power switch permitting absolutely safe connection and disconnection of electrical equipment with plug-and-play simplicity.
Safe & Reliable Plugs For Hazardous Areas
Marechal plugs combine electrical safety and reliability for power control and distribution in hazardous area industries where explosions are a real risk – plug and socket assemblies are suitable for flammable gases and vapours classified according to ATEX as Zone 1 & Zone 2 hazardous areas.
Decontactors = Plug + Socket-Outlet + Motor Load Make/Break Switch.No ordinary plugs and sockets, Marechal Decontactors permit safe connection and disconnection of electrical equipment from live power supply, with no requirement for hard-wiring or contactor.
Marechal DXN Plugs
Compact & Watertight Decontactor
Marechal DXN Plugs
Hazardous Area ATEX Certified Approved: Ex II2 G D Ex de IIC, Ex tb IIIC
Automatic IP66/IP67 water and dust tight decontactors
Integrated load break switch
Robust and compact design
High performance poly casing
20-63A plugs
550V-750V plug and socket outlet
Marechal DXA1 Plugs
Metal Decontactor
Marechal DXA1 Plugs
Hazardous Area ATEX Certified Approved: Ex II2 G D Ex de IIC, Ex tb IIIC
Automatic IP66/IP67 water and dust tight decontactors
Integrated load break switch
Locking in connected or disconnected by padlockable shaft
Intended for low temperature -55ºC
20A plugs
550V plug and socket outlet
Marechal DX Plugs
Metal Decontactor
Marechal DX Plugs
Hazardous Area ATEX Certified Approved: Ex II2 G D Ex de IIC, tD A21
Automatic IP65 water and dust tight decontactors
Integrated load break switch
Locking in connected or disconnected by keying axis
20-200A plugs
750V plug and socket outlet
Marechal PNCX Plugs
Compact Connectors & Plugs
Marechal PNCX Plugs
Hazardous Area ATEX Certified Approved: Ex II2 G D Ex de IIC, Ex tb IIIC
Electrical connector for harsh environments and hazardous areas (ATEX) and can be used in Zones 1 & 2 (gas) and Zone 21 & 22 (dust)
Compact and easy to use
IP66/IP67 watertight
Longlife
5A plugs
250V plug and socket outlet
Marechal PXN12C, DXN25C & DXN37C Plugs
Multi-Contact Connectors & Plugs
Marechal PXN12C, DXN25C & DXN37C Plugs
Hazardous Area ATEX Certified Approved: Ex II2 G D Ex de IIC, Ex tb IIIC
From 12 to 37 contacts
Locking in connected or disconnected position
Corrosion free metal casing
10A plugs
220-440V plug and socket outlet
Marechal SPex Connectors
Single Pole Power Connectors
Marechal SPex Connectors
Hazardous Area ATEX Certified Approved: Ex II2 G D Ex de IIC, Ex tb IIIC
IP65/IP66 water and dust tight
Electromechanical interlocking system
Mechanic and visual keying
235-680A plugs
1000V AC or 1500V DC plug and socket outlet
Power Plugs For Industry
Visit our Blog to discover how Marechal decontactors provide safe and reliable low voltage power to all industries.
➡ For complete information, specifications and technical data about Marechal Hazardous Area Plugsplease refer to the product sections below – contact T&D to discuss applications for hazardous area plugs and sockets for potentially explosive atmospheres including Zone 1 & Zone 2.
Control stations suitable for Zone 1 hazardous areas manufactured in GRP, stainless steel and plastic – suitable for safe installation in potentially explosive gas atmospheres, ATEX certified.
Zone 22 control stations for explosive dust atmospheres are available in both standard and bespoke configuration.
Control Stations – Zone 1 Zone 2 Hazardous Area ATEX Certified
Control Stations & Push Buttons
Hazardous area control stations, surface or panel mounted, specified for potentially explosive atmospheres and suitable for Zone 1 gas and Zone 21 dust environments (including Zone 2 & 22) – manufactured from stainless steel, plastic or GRP with various push buttons, emergency stops, switches, mushroom heads and indicator lamps integrated into control station. Bespoke solutions, express delivery.
Ex ed IIC T4
Ex e II T4
Control station options:
Emergency Stop Station
Emergency Power Off
Emergency Stop Start Station
Stop Station & Start Station (Stop/Start)
Key Suppliers: Abtech & Craig & Derricott
Technor hazardous area electrical equipment
For competitive pricing, delivery and technical support on the complete range of Technor Hazardous Area products, please contact T&D:
Lighting – Fluorescent, Wellglass, LED Lighting & Floodlights
➡ For complete information about Hazardous Area Control Stations please refer to the product sections below – contact T&D, The Hazardous Area & Explosive Atmosphere Experts, for a complete range of Electrical, Mechanical, Process & Instrumentation Equipment.
Zone 1 & Zone 2 GRP Assembled Enclosures & Junction Boxes – ATEX Hazardous Area
ATEX Enclosures
Abtech BPGA GRP assembled electrical enclosures and junction boxes are ATEX certified and suitable for Zone 1 and Zone 2 hazardous areas.
Abtech BPGA explosion proof junction boxes comprise of three types of BPG enclosure in two different size – are ATEX and IECEx certified Ex‘e’ and are suitable for use in Category 2/Zone 1 & 21 and Category 3/Zone 2 & 22 areas according to EN 60079-14.
The Abtech BPGA GRP range of hazardous area enclosures intended for explosive atmospheres are manufactured in impact resistant glass-reinforced polyester which has an ingress protection rating of IP66/67.
The BPGA enclosures are ideal for a range of uses such as lighting, power and instrument junction boxes.
atex Enclosures & Junction Boxes
Zone 1 & Zone 2 Hazardous area
Abtech BPGA Features
Junction Boxes & Enclosures
Ingress protected to IP66/67
Shell/ERA deluge tested
Measuring between 50 and 100mm in diameter
Fitted with a brass M6 internal/external earth stud
ATEX & IECEx compliant Ex‘e’ for use in Zone 1, 21,2 & 22 areas
Pre-drilled with four M20 tapped cable entries
Supplied with certified blanking plugs
Temperature Rating
-50°C to +40°C at T6
-50°C to +55°C at T5
Zone 1
A hazardous area zone location according to ATEX in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is likely to occur in normal operation occasionally.
Zone 2
A hazardous area zone location according to ATEX in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is not likely to occur in normal operation but, if it does occur, persists for a short period only.
ATEX Explained
The ATEX Directive consists of two EU directives describing the type of equipment and hazardous area location within a potentially explosive atmosphere. ATEX originates its name from the French title of the 94/9/EC directive: Appareils destinés à être utilisés en ATmosphères EXplosibles.
Cable entries can be drilled in the enclosure or junction box door, sides or via the cable gland plates – cable entries can also be drilled through the rear face of the stainless steel enclosure (EEx’e’ hazardous area versions).
The hazardous area enclosures include a hinged, lift-off door secured to the junction box using 4 captive stainless steel screws which also maintain the correct compression on the gasket.
Electrical Enclosure Junction Box
Zone 1 & Zone 2 GRP Assembled Enclosures & Junction Boxes – ATEX Hazardous Area
Hazardous Area Certification
Hazardous Area Enclosures: Intrinsically Safe Junction Boxes
Abtech BPGA enclosures are certified according to leading hazardous area classifications including:
ATEX & IECEx (Zone 1 & 2; Zone 21 & 22)
TR CU
NEMA 4X (CSA, UL & FM) Class 1 Division 2
T&D, The Explosive Atmosphere Experts, provide a single-source capability for the most extensive range of Electrical, Mechanical, Process & Instrumentation Equipment suitable for hazardous area locations.
Abtech BPGA stainless steel enclosures are certified according to international hazardous area classifications including UL, CSA, IEC Ex, ATEX, FM, InMetro and TR CU.
Hazardous Area Electrical Enclosures & Junction Boxes
If in doubt, please contact T&D for specification support and selection advice about hazardous area junction boxes and enclosures.
Abtech Part Number
Width (mm)
Height (mm)
Depth (mm)
Weight (g)
Cable Entries
Blanking Plugs
Terminals
Earth Continuity Plate
Earth Stud
BPGA120
122
120
90
1140
4 x M20 (2 x Side A, 2 x Side C)
4 off (Ex‘e’ rated)
6 x SAK 2.5 (linked in pairs)
Yes (Copper)
Yes (Brass, M6)
BPGA125
122
120
90
1140
4 x M20 (2 x Side A, 2 x Side C)
4 off (Ex‘e’ rated)
6 x WDU 2.5
Yes (Copper)
Yes (Brass, M6)
BPGA160
160
160
90
1740
4 x M20 (2 x Side A, 2 x Side C)
4 off (Ex‘e’ rated)
13 x SAK 2.5
Yes (Copper)
Yes (Brass, M6)
Configurations
Abtech Part Number
Width (mm)
Height (mm)
Depth (mm)
Weight (g)
Colour
Terminals
BPGA120
122
120
90
1140
Grey
6 x SAK 2.5
BPGA125
122
120
90
1140
Grey
6 x WDU 2.5
BPGA160
160
160
90
1740
Grey
13 x SAK 2.5
BPGA165
160
160
90
1740
Grey
13 x WDU 2.5
BPGCA120
122
120
90
1140
Black
6 x SAK 2.5
BPGCA125
122
120
90
1140
Black
6 x WDU 2.5
BPGCA160
160
160
90
1740
Black
13 x SAK 2.5
BPGCA165
160
160
90
1740
Black
13 x WDU 2.5
GRP Assembled Enclosures
Abtech BPGA enclosures come equipped with terminals (SAK 2.5 or WDU 6), rail, copper earth continuity plate and are also fitted with a brass M6 internal/external earth stud. Each enclosure has four M20 tapped cable entries (two side A & two side C) and is supplied with certified blanking plugs.
With international hazardous area classifications, including ATEX, Abtech BPGA GRP junction boxes and enclosures are suitable for onshore and offshore installation in both Zone 1 & Zone 2 hazardous area locations. T&D provide pre-assembled terminal enclosures for use as hazardous area lighting, power, heat tracing and instrument junction boxes with increased safety, intrinsically safe and flameproof explosion protection methods – we can custom supply high voltage enclosures for 3.3kV, 6.6kV, 11kV and 33kV networks.
Hazardous area IBC heater jackets with ATEX certification for safe use in potentially explosive atmospheres, including Zone 1 & Zone 2 locations – available from Thorne & Derrick. Our hazardous area container heaters ensure safe electrical heating of IBCs in chemical warehousing and flammable liquid storage locations.
Hazardous area IBC heater jackets from Thorne & Derrick can be used to heat IBC containers up to 60ºC. In order to assist and accelerate heating times, an insulated lid can additionally be supplied.
IBC heaters from T&D provide electrical heating and frost protection to liquids stored in IBCs – typically 1000 litre containers. T&D can provide a selection of ATEX IBC heater jackets suitable for different requirements and additionally can supply standard IBC Heating Jackets for non-hazardous areas.
IBC Heating Jacket Technical Specifications
Hazardous Area Zone 1 & Zone 2 ATEX Certified
Container heaters suitable for 1000-liter IBC-Container of all types and manufacturers.
Robust, flexible and dissipative construction for indoor and outdoor use
Standard and bespoke solutions available – heating jackets customised according to the required dimensions
Very robust, flexible and dissipative construction for indoor and outdoor use
Delivered completely configured and ready to use immediately without further acceptance procedures
Ambient temperatures from -40 °C to + 60 °C
Protection classes: gas IP65 / dust IP6X
Temperature class: T3
T&D’s Hazardous Area Team are CompEx trained and available to discuss your hazardous area heating requirements.
IBC Heating FAQs
What is an IBC Heater and how does it work?
IBC heaters are used to maintain the temperature of materials stored in Intermediate Bulk Containers. Learn how they work and which types are available.
Can IBC heaters be used in hazardous areas?
Some IBC heaters are suitable for hazardous environments. Discover the certifications and models designed for these applications.
How do I choose the right IBC heater for my application?
Selecting the correct IBC heater depends on several factors. Our technical team can help—find out what to consider.
➡ View the full range of Drum & IBC Heaters available from Thorne & Derrick
Press Release Date: 02.04.2020 uploaded by Chris Dodds (T&D Sales + Marketing Manager) World’s First Fully Certified ATEX Doors Thorne & Derrick International, the Experts in Equipment for Explosive Atmospheres, today announce the signing of a Commercial Distribution Agreement...
Press Release Date: 04.07.2019 uploaded by Chris Dodds (T&D Sales + Marketing Manager) Category: Stockist Distributor Agreement Announcement Thorne & Derrick International announce that they have signed a Preferred Distributor Agreement with Raytec, the world leading manufacturer of LED...