Our Products

IBC Heaters | Hazardous Area Zone 1 & Zone 2 ATEX Certified

IBC Heaters | Hazardous Area Zone 1 & Zone 2 ATEX Certified

ATEX Control Stations | Hazardous Area Stations for Zone 1 & Zone 2

ATEX Control Stations | Hazardous Area Stations for Zone 1 & Zone 2

ATEX Plugs | Hazardous Area Plugs & Sockets for Zone 1 & Zone 2

ATEX Plugs | Hazardous Area Plugs & Sockets for Zone 1 & Zone 2

Air Warmers & Fan Heaters | ATEX Zone 1 & Zone 2 Hazardous Area Heaters

Air Warmers & Fan Heaters | ATEX Zone 1 & Zone 2 Hazardous Area Heaters

ATEX Enclosures | Hazardous Area Junction Boxes for Zone 1 & Zone 2

ATEX Enclosures | Hazardous Area Junction Boxes for Zone 1 & Zone 2

ATEX Lighting | Hazardous Area Lighting for Zone 1 & Zone 2

ATEX Lighting | Hazardous Area Lighting for Zone 1 & Zone 2

ATEX Lighting Hazardous Area Lighting Zone 1 Zone 2 ATEX

Lighting | ATEX Certified for Hazardous Areas

ATEX Lighting

Thorne & Derrick International, based in the UK, are the leading supplier of ATEX Lighting for safe and reliable installation in hazardous areas and locations – this includes Lighting for hazardous areas certified by the ATEX Directive for use in Zone 1 and Zone 2 potentially explosive atmospheres in both onshore and offshore locations Zone 1 & 2 Flammable Gas and Zone 21 & 22 (Combustible Dust).

We are Main Distributors for Raytec – this includes ATEX Lighting product groups: Floodlights, Linear Light Fittings, Bulkheads & High Bay.

A complete range of portable lighting for temporary applications with ATEX and IECEx Certification is available – the Wolf Safety Safety Lamp Company provide safe lighting products for use in potentially explosive atmospheres where the presence of flammable gas, vapour or dusts pose a potential explosion risk.

Lighting products are available for Zone 0, Zone 1 (21) and Zone 2 (22) hazardous area classifications according to the ATEX Directive. 

Lighting

Hazardous area lighting for safe use in potentially explosive atmospheres, including Zones 1 / 2 (gases) and Zones 21 / 22 (dusts) certified to ATEX and IECEx.

  • Fluorescent or LED – Emergency, Bulkhead, Well Glass & Floodlights
  • Portable – Handlamps, Torches, Headtorches & Floodlights
  • Temporary Floodlights, Tanklights, Airlamps & Mobile Lighting

Wolf Floodlights Handlamps Tank Lighting - Hazardous Area Zone 1 Zone 2 ATEX

Wolf Torches Headlamps Handlamps - Hazardous Area Zone 1 Zone 2 ATEX

Hazardous Area ATEX  | Portable & Temporary Lighting | Wolf Safety Lamp Stockist

Hazardous Area ATEX Lighting Zone 1 Zone 2

The SPARTAN range of lighting manufactured by Raytec is designed for lighting hazardous areas which require high performance, high reliability, White-Light illumination using LED technology – ATEX Certified Zone 1 & Zone 2.

What Is ATEX?

ATEX  is “ATmosphere EXplosible”

ATEX is the name commonly given to the two European Directives for controlling explosive atmospheres: 1) Directive 99/92/EC (also known as ‘ATEX 137’ or the ‘ATEX Workplace Directive’) on minimum requirements for improving the health and safety protection of workers potentially at risk from explosive atmospheres working in hazardous area industries. The ATEX Zones for lighting products are designated either Zone 1 or Zone 2 depending on the exposure threat to flammable gases or vapours – accordingly these hazardous area lighting systems must be correctly specified according to the level of explosion. Classifying hazardous areas into Zones:

Zone 1 v Zone 2

Hazardous Areas

ATEX

Zone 1: is a hazardous area classified by ATEX in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is likely to occur in normal operation occasionally.

Zone 2: is a hazardous area classified by ATEX in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is not likely to occur in normal operation but, if it does occur, persists for a short period only.

Overview of ATEX Lighting products:

Hazardous areas are classified in terms of zones on the basis of the frequency and duration of the occurrence of an explosive atmosphere.

Hazardous Area Floodlights

SPARTAN Floodlights have been specified and installed to provide lighting to hazardous area locations and workspaces on an offshore Jack-up drilling rig which had been brought in for maintenance in the Middle East. General illumination of this rig, including ATEX floodlights and lighting for access areas and walkways, was a necessity for the safety and efficiency of the workers. All SPARTAN emergency lighting products, manufactured by Raytec, installed provided 100% light output for 1 hour with both IECEx and ATEX Certification.

How Can We Help?

The following video provides an excellent presentation of the Raytec SPARTAN range of Hazardous Area LED Lighting Products for Zone 1 & Zone 2 (ATEX) – high lumen output is provided by the latest high performance LED technology delivering low running costs and low energy consumption. The modular design hazardous area ATEX lighting system is specified to provide ease of maintenance and inspection with spare part availability for quick repair and replacement of light fixtures and fittings.

 

 

Raytec

T&D are stockists and suppliers of an extensive range of Hazardous Area Electrical Equipment – this includes explosion proof (Ex e) and flameproof (Ex d) products certified by ATEX for use in hazardous areas and explosive atmospheres:

➡ Our Lighting Sales Team are trained and manufactured approved to provide technical support and lighting specification services covering Hazardous Area Zone or Category, Type of Explosion Protection, Gas Group, Temperature Class (T Class Rating) and Equipment Protection Level concepts.


Lighting Designs For Hazardous Areas

Upgrading Plant Legacy Lighting to LED

Thorne & Derrick International, based in the UK, are leading Stockists & Distributors of hazardous area lighting products utilising conventional light fittings and more powerful modern technology White-Light illumination using LED technology – from stock we provide competitive prices and technical support to enable the specification of explosive atmosphere lighting schemes compliant and certified to international standards including ATEX and IECEx.

Using latest software our FREE Lighting Design Service supports the upgrade from fluorescent to LED lighting focussed on maximised light output, optimised energy consumption with reliable and safe certification for explosion protection concepts in Zone 1 and Zone 2 hazardous area zones and workplaces.

Hazardous Area Lighting

T&D, The Hazardous Area Experts | ATEX Plugs Sockets | ATEX Isolators | ATEX Heaters | ATEX Enclosures

Hazardous Area Plugs - Zone 1 & Zone 2 Plugs, Sockets & Connectors (Explosion Proof - ATEX & IECEx)

Hazardous Area Plugs – Zone 1 & Zone 2 Plugs, Sockets & Connectors (Explosion Proof – ATEX & IECEx)

High Current PlugsHigh Temperature PlugsATEX

Marechal hazardous area plugs and sockets offer an extensive and comprehensive product range for all industrial electrical power applications in Zone 1 & Zone 2 Hazardous Areas with power currents varying from 10A to 680A with up to 1,500 volt power supplies – ATEX certified plugs and sockets.

Typical applications for explosion-proof hazardous area plugs include mobile machinery, portable plant, wellhead control panels, mobile skid units and offshore heavy power, data and signal distribution.

ATEX Plugs & Sockets

Hazardous Areas

Thorne & Derrick are Approved Main Distributors for Marechal Hazardous Area Plugs – contact us for competitive prices, fast delivery and expert technical support to enable the selection and specification of the correct plug, socket or decontactor for all industrial and hazardous area power distribution applications.

A Decontactor® is a plug and socket outlet system with an integrated power switch permitting absolutely safe connection and disconnection of electrical equipment with plug-and-play simplicity.

Safe & Reliable Plugs For Hazardous Areas

Marechal plugs combine electrical safety and reliability for power control and distribution in hazardous area industries where explosions are a real risk – plug and socket assemblies are suitable for flammable gases and vapours classified according to ATEX as Zone 1 & Zone 2 hazardous areas.

Hazardous Areas

Safe With Marechal & Technor

Watch our Marechal video providing an overview of EX products certified for hazardous areas including plug-socket outlets, lighting, control stations (Zone 2), junction boxes, flameproof Exd electrical enclosures and electrical socket boxes

Hazardous Area Plugs - Zone 1 & Zone 2 Plugs, Sockets & Connectors (Explosion Proof - ATEX & IECEx)

Decontactors = Plug + Socket-Outlet + Motor Load Make/Break Switch. No ordinary plugs and sockets, Marechal Decontactors permit safe connection and disconnection of electrical equipment from live power supply, with no requirement for hard-wiring or contactor.

Marechal DXN Plugs

Compact & Watertight Decontactor

Marechal DXN Plugs Compact & Watertight Decontactor

Marechal DXN Plugs

  • Hazardous Area ATEX Certified Approved: Ex II2 G D Ex de IIC, Ex tb IIIC
  • Automatic IP66/IP67 water and dust tight decontactors
  • Integrated load break switch
  • Robust and compact design
  • High performance poly casing
  • 20-63A plugs
  • 550V-750V plug and socket outlet

Marechal DXA1 Plugs

Metal Decontactor

Marechal DXA1 Plugs Decontactor for Industry

Marechal DXA1 Plugs

  • Hazardous Area ATEX Certified Approved: Ex II2 G D Ex de IIC, Ex tb IIIC
  • Automatic IP66/IP67 water and dust tight decontactors
  • Integrated load break switch
  • Locking in connected or disconnected by padlockable shaft
  • Intended for low temperature -55ºC
  • 20A plugs
  • 550V plug and socket outlet

Marechal DX Plugs

Metal Decontactor

Marechal DX Plugs Metal Decontactor

Marechal DX Plugs

  • Hazardous Area ATEX Certified Approved: Ex II2 G D Ex de IIC, tD A21
  • Automatic IP65 water and dust tight decontactors
  • Integrated load break switch
  • Locking in connected or disconnected by keying axis
  • 20-200A plugs
  • 750V plug and socket outlet

Marechal PNCX Plugs

Compact Connectors & Plugs

Marechal PNCX Plugs Compact Connectors & Plugs

Marechal PNCX Plugs

  • Hazardous Area ATEX Certified Approved: Ex II2 G D Ex de IIC, Ex tb IIIC
  • Electrical connector for harsh environments and hazardous areas (ATEX) and can be used in Zones 1 & 2 (gas) and Zone 21 & 22 (dust)
  • Compact and easy to use
  • IP66/IP67 watertight
  • Longlife
  • 5A plugs
  • 250V plug and socket outlet

Marechal PXN12C, DXN25C & DXN37C Plugs

Multi-Contact Connectors & Plugs

Marechal PXN12C Plugs Connectors & Plugs

Marechal PXN12C, DXN25C & DXN37C Plugs

  • Hazardous Area ATEX Certified Approved: Ex II2 G D Ex de IIC, Ex tb IIIC
  • From 12 to 37 contacts
  • Locking in connected or disconnected position
  • Corrosion free metal casing
  • 10A plugs
  • 220-440V plug and socket outlet

Marechal SPex Connectors

Single Pole Power Connectors

Marechal SPex Connectors Single Pole Power Connectors

Marechal SPex Connectors

  • Hazardous Area ATEX Certified Approved: Ex II2 G D Ex de IIC, Ex tb IIIC
  • IP65/IP66 water and dust tight
  • Electromechanical interlocking system
  • Mechanic and visual keying
  • 235-680A plugs
  • 1000V AC or 1500V DC plug and socket outlet
Power Plugs For Industry

Visit our Blog to discover how Marechal decontactors provide safe and reliable low voltage power to all industries.

➡ For complete information, specifications and technical data about Marechal Hazardous Area Plugs please refer to the product sections below – contact T&D to discuss applications for hazardous area plugs and sockets for potentially explosive atmospheres including Zone 1 & Zone 2.

➡ See also: ATEX Isolators | ATEX Junction Boxes & Enclosures | Exd Enclosures Flameproof

Plugs Sockets - Food Beverage - Marechal

Food & Beverage. Waterproof plugs (IP66 IP67) withstand high pressure cleaning, spray and humidity.

Plugs Sockets - Oil & Gas - Marechal

Oil & Gas. ATEX plugs certified for hazardous area Zones 1/2 (gas) and Zones 21/22 (dust).

Plugs Sockets - Construction - Marechal

Heavy Industry. Electrical power plugs up to 750A with safe disconnect under load.

ATEX Control Stations

ATEX Control Stations For Hazardous Areas

ATEX Control Stations

Thorne & Derrick International, based in the UK, are Main Distributors for Abtech Electrical Equipment including hazardous area lighting, control stations and electrical enclosures (ATEX Certified).

Control stations suitable for Zone 1 hazardous areas manufactured in GRP, stainless steel and plastic – suitable for safe installation in potentially explosive gas atmospheres, ATEX certified.

Zone 22 control stations for explosive dust atmospheres are available in both standard and bespoke configuration.

Control Stations -  Zone 1 Zone 2 Hazardous Area ATEX Certified

Control Stations –  Zone 1 Zone 2 Hazardous Area ATEX Certified

Control Stations & Push Buttons

Hazardous area control stations, surface or panel mounted, specified for potentially explosive atmospheres and suitable for Zone 1 gas and Zone 21 dust environments (including Zone 2 & 22) – manufactured from stainless steel, plastic or GRP with various push buttons, emergency stops, switches, mushroom heads and indicator lamps integrated into control station. Bespoke solutions, express delivery.

  • Ex ed IIC T4
  • Ex e II T4 

Control station options:

  • Emergency Stop Station
  • Emergency Power Off
  • Emergency Stop Start Station
  • Stop Station & Start Station (Stop/Start)
Key Suppliers: Abtech & Craig & Derricott
Technor hazardous area electrical equipment

For competitive pricing, delivery and technical support on the complete range of Technor Hazardous Area products, please contact T&D:

Technor Hazardous Area Electrical Equipment

Technor Hazardous Area Equipment – T&D distribute electrical enclosures, lighting luminaires, electrical panels and control stations.

T&D can also supply and deliver high voltage hazardous area enclosures for 3.3kV, 6.6kV, 11kV and 33kV HV distribution networks.

ATEX Control Stations

➡ For complete information about Hazardous Area Control Stations please refer to the product sections below – contact T&D, The Hazardous Area & Explosive Atmosphere Experts, for a complete range of Electrical, Mechanical, Process & Instrumentation Equipment.

Zone 1 & Zone 2 GRP Assembled Enclosures & Junction Boxes - ATEX Hazardous Area

Zone 1 & Zone 2 GRP Assembled Enclosures & Junction Boxes – ATEX Hazardous Area

ATEX Enclosures

Abtech BPGA GRP assembled electrical enclosures and junction boxes are ATEX certified and suitable for Zone 1 and Zone 2 hazardous areas.

Abtech BPGA explosion proof  junction boxes comprise of three types of BPG enclosure in two different size – are ATEX and IECEx certified Ex‘e’ and are suitable for use in Category 2/Zone 1 & 21 and Category 3/Zone 2 & 22 areas according to EN 60079-14.

The Abtech BPGA GRP range of hazardous area enclosures intended for explosive atmospheres are manufactured in impact resistant glass-reinforced polyester which has an ingress protection rating of IP66/67.

The BPGA enclosures are ideal for a range of uses such as lighting, power and instrument junction boxes.

atex Enclosures & Junction Boxes

Zone 1 & Zone 2 Hazardous area

Abtech BPGA Features

Zone 1 Zone 2 Hazardous Area Junction Box Enclosures

Junction Boxes & Enclosures

  • Ingress protected to IP66/67
  • Shell/ERA deluge tested
  • Measuring between 50 and 100mm in diameter
  • Fitted with a brass M6 internal/external earth stud
  • ATEX & IECEx compliant Ex‘e’ for use in Zone 1, 21,2 & 22 areas
  • Pre-drilled with four M20 tapped cable entries
  • Supplied with certified blanking plugs

Temperature Rating

  • -50°C to +40°C at T6
  • -50°C to +55°C at T5

Zone 1

A hazardous area zone location according to ATEX in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is likely to occur in normal operation occasionally.

Zone 2

A hazardous area zone location according to ATEX in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is not likely to occur in normal operation but, if it does occur, persists for a short  period only.

ATEX Explained

The ATEX Directive consists of two EU directives describing the type of equipment and hazardous area location within a potentially explosive atmosphere. ATEX originates its name from the French title of the 94/9/EC directive: Appareils destinés à être utilisés en ATmosphères EXplosibles.

Cable entries can be drilled in the enclosure or junction box door, sides or via the cable gland plates – cable entries can also be drilled through the rear face of the stainless steel enclosure (EEx’e’ hazardous area versions).

The hazardous area enclosures include a hinged, lift-off door secured to the junction box using 4 captive stainless steel screws which also maintain the correct compression on the gasket.

Electrical Enclosure Junction Box

Zone 1 & Zone 2 GRP Assembled Enclosures & Junction Boxes - ATEX Hazardous Area

Zone 1 & Zone 2 GRP Assembled Enclosures & Junction Boxes – ATEX Hazardous Area

Hazardous Area Certification

Hazardous Area Enclosures: Intrinsically Safe Junction Boxes

Hazardous Area Enclosures: Intrinsically Safe Junction Boxes

Abtech BPGA enclosures are certified according to leading hazardous area classifications including:

  • ATEX & IECEx (Zone 1 & 2; Zone 21 & 22)
  • TR CU
  • NEMA 4X (CSA, UL & FM) Class 1 Division 2

T&D, The Explosive Atmosphere Experts, provide a single-source capability for the most extensive range of Electrical, Mechanical, Process & Instrumentation Equipment suitable for hazardous area locations.

Hazardous Area Coding & Zones Zone 0 Zone 20 Zone 1 Zone 21 Zone 2 Zone 22
Ex e
Ex ai Intrinsic Safety
Ex ab
Ex op is
Ex nA
Ex nR

Abtech BPGA stainless steel enclosures are certified according to international hazardous area classifications including UL, CSA, IEC Ex, ATEX, FM, InMetro and TR CU.

Hazardous Area Electrical Enclosures & Junction Boxes

Hazardous Area Electrical Enclosures & Junction Boxes

Enclosures

Abtech BPGA Junction Boxes Selection Table

If in doubt, please contact T&D for specification support and selection advice about hazardous area junction boxes and enclosures.

Abtech Part Number Width (mm) Height (mm) Depth (mm) Weight (g) Cable Entries Blanking Plugs Terminals Earth Continuity Plate Earth Stud
BPGA120 122 120 90 1140 4 x M20 (2 x Side A, 2 x Side C) 4 off (Ex‘e’ rated) 6 x SAK 2.5 (linked in pairs) Yes (Copper) Yes (Brass, M6)
BPGA125 122 120 90 1140 4 x M20 (2 x Side A, 2 x Side C) 4 off (Ex‘e’ rated) 6 x WDU 2.5 Yes (Copper) Yes (Brass, M6)
BPGA160 160 160 90 1740 4 x M20 (2 x Side A, 2 x Side C) 4 off (Ex‘e’ rated) 13 x SAK 2.5 Yes (Copper) Yes (Brass, M6)

 

Configurations

Abtech Part Number Width (mm) Height (mm) Depth (mm) Weight (g) Colour Terminals
BPGA120 122 120 90 1140 Grey 6 x SAK 2.5
BPGA125 122 120 90 1140 Grey 6 x WDU 2.5
BPGA160 160 160 90 1740 Grey 13 x SAK 2.5
BPGA165 160 160 90 1740 Grey 13 x WDU 2.5
BPGCA120 122 120 90 1140 Black 6 x SAK 2.5
BPGCA125 122 120 90 1140 Black 6 x WDU 2.5
BPGCA160 160 160 90 1740 Black 13 x SAK 2.5
BPGCA165 160 160 90 1740 Black 13 x WDU 2.5

 

GRP Assembled Enclosures

Abtech BPGA enclosures come equipped with terminals (SAK 2.5 or WDU 6), rail, copper earth continuity plate and are also fitted with a brass M6 internal/external earth stud. Each enclosure has four M20 tapped cable entries (two side A & two side C) and is supplied with certified blanking plugs.

Hazardous Area Zone 1 Zone 2 Enclosure Junction Box

With international hazardous area classifications, including ATEX, Abtech BPGA GRP junction boxes and enclosures are suitable for onshore and offshore installation in both Zone 1 & Zone 2 hazardous area locations. T&D provide pre-assembled terminal enclosures for use as hazardous area lighting, power, heat tracing and instrument junction boxes with increased safety, intrinsically safe and flameproof explosion protection methods – we can custom supply high voltage enclosures for 3.3kV, 6.6kV, 11kV and 33kV networks.

Hazardous Area IBC Heater Jackets

Contact us today to discuss your ATEX IBC heating requirements.

Hazardous Area IBC Heater Jackets

ATEX Certification

Hazardous area IBC heater jackets with ATEX certification for safe use in potentially explosive atmospheres, including Zone 1 & Zone 2 locations – available from Thorne & Derrick. Our hazardous area container heaters ensure safe electrical heating of IBCs in chemical warehousing and flammable liquid storage locations.

Hazardous area IBC heater jackets from Thorne & Derrick can be used to heat IBC containers up to 60ºC. In order to assist and accelerate heating times, an insulated lid can additionally be supplied.

IBC heaters from T&D provide electrical heating and frost protection to liquids stored in IBCs – typically 1000 litre containers. T&D can provide a selection of ATEX IBC heater jackets suitable for different requirements and additionally can supply standard IBC Heating Jackets for non-hazardous areas.


IBC Heating Jacket Technical Specifications

Hazardous Area Zone 1 & Zone 2 ATEX Certified

  • Container heaters suitable for 1000-liter IBC-Container of all types and manufacturers.
  • Robust, flexible and dissipative construction for indoor and outdoor use
  • Standard and bespoke solutions available – heating jackets customised according to the required dimensions
  • Very robust, flexible and dissipative construction for indoor and outdoor use
  • Delivered completely configured and ready to use immediately without further acceptance procedures
  • Ambient temperatures from -40 °C to + 60 °C
  • Protection classes: gas IP65 / dust IP6X
  • Temperature class: T3

T&D’s Hazardous Area Team are CompEx trained and available to discuss your hazardous area heating requirements.

IBC Heating FAQs


What is an IBC Heater and how does it work?

IBC heaters are used to maintain the temperature of materials stored in Intermediate Bulk Containers. Learn how they work and which types are available.


Can IBC heaters be used in hazardous areas?

Some IBC heaters are suitable for hazardous environments. Discover the certifications and models designed for these applications.


How do I choose the right IBC heater for my application?

Selecting the correct IBC heater depends on several factors. Our technical team can help—find out what to consider.


➡ View the full range of Drum & IBC Heaters available from Thorne & Derrick

Blog

Thorne & Derrick & Raytec | Together Safely Lighting Hazardous Areas

Published 04 Jul 2019

Thorne & Derrick & Raytec | Together Safely Lighting Hazardous Areas

Press Release Date: 04.07.2019 uploaded by Chris Dodds (T&D Sales + Marketing Manager) Category: Stockist Distributor Agreement Announcement Thorne & Derrick International announce that they have signed a Preferred Distributor Agreement with Raytec, the world leading manufacturer of LED...

Read More

Associated manufacturers
Enquire
X

Get a quote

Complete the form below to make an enquiry about products.

  • Please enter your full name.
  • Please enter your contact telephone number.
  • Please enter your e-mail address.
  • Please select if you are enquiring about products for the UK or for export.
  • This field is for validation purposes and should be left unchanged.