Our Products

IBC Heaters | Hazardous Area Zone 1 & Zone 2 ATEX Certified

IBC Heaters | Hazardous Area Zone 1 & Zone 2 ATEX Certified

Air Warmers & Fan Heaters | ATEX Zone 1 & Zone 2 Hazardous Area Heaters

Air Warmers & Fan Heaters | ATEX Zone 1 & Zone 2 Hazardous Area Heaters

ATEX Enclosures | Hazardous Area Junction Boxes for Zone 1 & Zone 2

ATEX Enclosures | Hazardous Area Junction Boxes for Zone 1 & Zone 2

ATEX Lighting | Hazardous Area Lighting for Zone 1 & Zone 2

ATEX Lighting | Hazardous Area Lighting for Zone 1 & Zone 2

ATEX Plugs | Hazardous Area Plugs & Sockets for Zone 1 & Zone 2

ATEX Plugs | Hazardous Area Plugs & Sockets for Zone 1 & Zone 2

ATEX Control Stations | Hazardous Area Stations for Zone 1 & Zone 2

ATEX Control Stations | Hazardous Area Stations for Zone 1 & Zone 2

Hazardous Area Safety Showers

Hazardous Area Safety Showers – Aqua Safety

Hazardous Area Safety Showers

Safety Showers are specified worldwide throughout the Oil, Gas and Petrochemical industries, providing workforce protection against risks and hazards in potentially explosive atmospheres as well as industrial areas. Emergency Safety showers provide an on-the-spot decontamination unit so workers are able to safely flush away corrosive solutions or substances that may otherwise cause personal injury.

âž¡ Contact Thorne & Derrick for the full range of ATEX & Industrial Safety Showers from Aqua Safety Showers

Safety showers certified according to the ATEX Hazardous Area Directive are available with immersion heaters on self-contained tank showers and trace heating tape on mains fed units to provide frost protection against low temperatures.

Aqua safety offer a fast solution when workers have been exposed to hazardous substances. These hazardous area safety showers provide an excellent solution when quick reactions are crucial to minimise the risk of serious injuries.

Manufactured in the UK, and using only the highest quality locally-sourced materials, the range is offered in different sizes and capacities with all models meeting or exceeding ANSI Z358.1 2014 standards:

  • ANSI/ISEA Z358.1-2014 American National Standard for Emergency Eyewash & Shower Equipment

Aqua Tank Showers guarantee over 15 minutes of tepid water without the need for a mains water supply. Tank showers are ideal for use outside in areas such as large industrial complexes where a mains water supply would be costly and hard to install. The full range includes models suitable for any environment, whether hazardous or non-hazardous area, remote locations or extreme temperatures (-55°C to +50°C / -67°F to +122°F).


Tank Safety Showers

350L Tank Shower

350L Emergency Tank Shower

Model: Aqua TS350

Self-contained 350L emergency tank shower, suitable for indoor, outdoor, hazardous and non-hazardous areas.

  • Delivers over 5 minutes of tepid water without a mains water supply
  • Used in temperatures of -25°C to +35°C
  • 76lpm flow rate

 

1500L Tank Shower Aqua Safety Showers

1500L Emergency Tank Shower

Model: Aqua TS1500

Self-contained 1500L Tank-fed safety shower with GRP header tank and stainless steel framework.

  • Delivers over 15 minutes of tepid water without a mains water supply
  • Robust and corrosion resistant
  • Used in temperatures of -25°C to +35°C

 

 

2500L Tank Safety Shower Aqua2500L Emergency Tank Shower

Model: Aqua TS2500

2500L Hazardous Area Emergency Tank Shower for indoor and outdoor use. Also suitable for non-hazardous areas.

  • Guarantees over 30 minutes of tepid water at correct pattern and flow rate
  • Robust and corrosion resistant
  • Highly visible in all conditions

 

Remote Heater Tank Shower

Remote Header Tank

Model: Aqua RT350 / RT1500 / RT2500

Self-contained remote heater tank, available in 3 sizes (350L, 1500L, 2500L).

  • Indoor, Outdoor, Hazardous/Non-Hazardous Areas
  • Tepid water guaranteed to supply free-standing showers
  • Meets and exceeds ANSI and EN standards

 

 

Non-Hazardous Tank Shower

Tank Shower With Water Chiller (Non-Hazardous)

Model: Aqua TS1500CN

Self-contained 1500L Tank Safety Shower for extreme climates. Suitable for use in climates up to +55°C in non-hazardous areas.

  • Guarantees over 15 minutes of tepid water at correct pattern and flow rate
  • Water chiller keeps water at 20°C, day or night, which helps to reduce the growth of bacteria
  • Robust and corrosion resistant

 

Hazardous Area Tank Shower

Tank Shower With Water Chiller (Hazardous Areas)

Model: Aqua TS1500CH

Self-contained Tank Safety Shower for extreme climates. Suitable for use in climates up to +55°C in hazardous areas.

  • Guarantees over 15 minutes of tepid water at correct pattern and flow rate
  • Water chiller keeps water at 20°C, day or night, which helps to reduce the growth of bacteria
  • 1500L

 

Arctic Tank Shower

Artic Tank Shower

Model: Aqua TS1500A

Self-contained Tank Safety Shower for extreme climates indoor and outdoor. Suitable for use up to +55°C in hazardous areas and non-hazardous areas.

  • Guarantees over 15 minutes of tepid water at correct pattern and flow rate
  • Comes with water level and temperature gauge as standard
  • Specifically designed for extreme cold climates

Why use Safety Showers and Eyewash Stations?

Safety showers/eyewash stations are a vital piece of safety equipment used to mitigate the effects of exposure to polluting substances, providing the first line of defence from chemical splashes and burns in hazardous and industrial areas. Skin and eye burns caused by corrosive liquids, abrasive dust or polluting gases can cause serious harm; and any delays in treatment could have serious consequences.

Safety showers provide an on the spot decontamination unit allowing the user to flush away any harmful substances – quick reactions are crucial as they help to decrease the seriousness of the injury. Chemical splashes should be rinsed immediately before seeking further medical treatment.

Aqua Safety Showers


EXPERTS IN EQUIPMENT FOR EXPLOSIVE ATMOSPHERESExplosive Atmospheres

LEADERS IN ATEX INNOVATION TO THE HAZARDOUS AREA INDUSTRIES

Thorne & Derrick are leaders in the development and distribution of Product Innovations that deliver significant improvements to clients plant, people and operational safety in the explosive atmosphere industries.

Your proactive problem solvers experienced in succession planning for the replacement of obsolete, non-conformant and legacy equipment in hazardous areas.

Your first-choice provider of innovative and competitive solutions to ensure ATEX & IECEx Compliance for Hazardous Area Electrical, HVAC & Process Instrumentation Equipment to UK and international projects.

Hazardous Area Electrical Equipment

Drum Heating Jacket

Insulation Jackets

uploaded by Chris Dodds | Sales & Marketing Manager

Heating Jackets | Custom & Standard | Available From Stock | Contact Us Today

Heating jackets are manufactured according to our own Heatfast brand specifications using heat tracing cables and thermal insulation jackets – these heating jackets are used to provide frost protection, conserve heat and maintain plant process temperatures to prevent viscosity loss, coagulation, clogging or freezing.

The heat tracing cables are embedded to the thermal insulation jacket to provide even electrical surface heating and distribution – we can customise Trace Heatingdesign to specific applications and produce in-house for fast delivery to UK and international locations.


What Is Heat Tracing?

Electric heat tracing is a cable based system used to maintain, raise temperature and protect process pipework and vessels against freezing temperatures and associated frost damage – heat tracing cables mitigate and counteract cold weather effects as part of a Winterization strategy for industrial and process applications against low (sub-zero) ambient temperatures on both onshore and offshore locations.

This includes ATEX heaters to provide safe portable, hazardous area certified heating and air warming for Zone 1, Zone 2, Zone 21 and Zone 22 hazardous areas.

Typical Heating Jacket

Applications

Pipework heating and frost protection for fittings, junction boxes, drums, IBC’s, flanges, valves and associated mechanical process plant.

Our Heatfast jacket technology can be evolved and adapted to suit heating applications for non-standard Heat Tracingvariations and bespoke applications – fats, oils and foodstuffs are typically heated as well as organic and inorganic chemicals and acids in hazardous area zones and potentially explosive atmosphere locations.

Contact us to discuss the initial concept, agree a bespoke design, start manufacture and deliver on short lead times to support your Winterisation measures to prevent cold-weather damage to your critical process assets.

We have all the answers to your process heating questions.

  • How can I heat the contents of my storage units to allow pumping and processing?
  • What is the best way to guarantee frost protection for my vital mechanical engineering processes?
  • Where is the most time and maintenance efficient heating option I can incorporate in to my design requirements?

Thorne & Derrick distribute process heating products to enable the free flow of viscous liquids or gases by IBC, drum, pipe or heated hose.

Some Features & Benefits

  • Heat loss calculations can be conducted to ensure guaranteed process heating, temperature maintenance or frost protection
  • Jackets fitted with adjustable quick release buckle system for quick removal and maintenance and inspection
  • Heat tracing jackets available with ancillary accessories and size variations
  • Commonly referred to as trace heating jackets to retain heat energy and maintain storage and production efficiency

Fire Hydrant & Fire Extinguisher Protection – our Heatfast winterisation heating jackets can be used on fire extinguishers to provide frost protection and prevention of snow and ice build-up which could inflict “bursts” or freezing to critical safety equipment.

Engine Maintenance – our Heatfast heating jackets can be used to prevent fuel “waxing” in cold and sub-zero temperatures. Customised jacket heaters can be designed to include removable sections for engineering maintenance.

Pipe, Valve & Flange Maintenance – insulation jackets using Heatfast trace heating cables can be installed on onshore and offshore flanges, pipes and valves to provide winter protection against frost, snow, ice and environmental considerations.


Some Examples of Our Heating Products

Tank Heating Jackets

Tank Heating Jackets

Customised Insulation Jackets Using Heat Tracing Cables

Customised Insulation Jackets Using Heat Tracing Cables

Pump Heating Jackets

Pump Heating Jackets

Oscillator Monitor Covers

Oscillator Monitor Covers

Tank Cladding & Mats

Tank Cladding & Mats

 

Heating Jackets

Largest UK Stocks | Drum Heaters | IBC Heaters

 

Silicone Heaters | Mats & Pads | UK & Export Sales. Technical Support. Best Prices. Ex Stock.


Trace Heating Systems & Heat Trace Cables

The heat trace cable ranges stocked and supplied by Thorne & Derrick International includes electric heating cables for process temperature maintenance, pipe and vessel freeze protection and roof and gutter de-icing applications where snow and ice removal is required – cables and systems are available for commercial, industrial safe area (non-hazardous area) and hazardous area heating applications with ATEX certification.

Electric heat tracing is a cable based system used to maintain, raise temperature and protect process pipework and vessels against freezing temperatures and associated frost damage.

Heat tracing systems utilising self-regulating, constant wattage and mineral insulated (MI) heating cables are available to provide the optimum electrical heating system for your application – we provide a trace heating system design service.

Heat Trace Cables: Ramp Heating | Roof & Gutter Heating | Water Pipework Frost Protection | Hopper Heating | Tank Heating | Hazardous Area Heating | Fire Escapes

Trace Heating & Heat Tracing Cable Systems Specialists | Thorne & Derrick

EXPERTS IN WINTERISATION SOLUTIONS FOR INDUSTRIAL & HAZARDOUS AREA ENVIRONMENTS

Heat Tracing I Frost Protection

Thorne & Derrick hold the largest UK stocks of frost protection & winterisation equipment to help keep your plant and personnel operational during the winter months.

Thorne & Derrick understand that prolonged periods of low ambient temperatures can bring operations to a standstill costing thousands of pounds in lost downtime.

Experts in heating solutions for use in industrial & explosive atmospheres, Thorne & Derrick have the knowledge & expertise to help clients prevent unnecessary down time this winter.

We can provide overnight delivery of Trace Heating Cables at the most competitive prices to guarantee frost protection of your pipelines and mechanical services.| Ask About Our Heat Trace Design Service.

💡 Contact us today and our skilled and friendly team can provide technical support as well as reliable, fit for purpose and compliant solutions to suit your exact requirements.

Trace Heating | Process Heating | Heating Jackets | Drum & IBC Heaters | Heated Hoses |Silicone Heating Mats

➡See our Winterisation blog TOP PICKS, including our most read articles about Trace Heating and the requirement for electrical heating products and systems to combat and mitigate Winter weather effects.

Winter heating 2021

Competitive Prices | Extensive Stocks | Technical Support | Express Delivery

ATEX Heater EXHEAT LFH

EXHEAT Fan Heaters | Distributed from Stock | International Delivery | Competitive Prices | Contact Us Today

  • uploaded by Chris Dodds (Thorne & Derrick Sales Marketing Manager)

DSEAR

DSEAR Compliant Heaters

DSEAR stands for the Dangerous Substances and Explosive Atmospheres Regulations 2002.

Dangerous substances put peoples’ safety at risk from fire, explosion and corrosion of metal. DSEAR puts duties on employers to protect people from these risks and ensure their safety in the workplace, and to members of the public who may be put at risk by work activity. THE HSE usually recommends that DSEAR is updated every 3-5 years dependent upon the risk levels of the operations.

Compliance with DSEAR encompasses many facets of business activity including:

  • Risk assessment of plant operations
  • Defining of any hazardous zones together
  • Installation of hazard compliant equipment
  • Preparation of explosion protection records

HSE

According to the HSE fires and explosions are one of the main causes of deaths and damage in vehicle repair operations where the workspace has been designated as a potentially explosive atmosphere – this is according to UK DSEAR regulations and the European ATEX Directive.

Usually, the potential risk of explosion involves the mishandling of petrol eg when draining fuel tanks and lines, but incidents have also occurred during ‘hot work’ repairs on vehicle diesel tanks and waste oil storage tanks, during the inappropriate use of paints, thinners or waste petrol to ignite rubbish fires and the use of waste engine oil in space heaters.

Similarly, there is an explosion risk in aircraft hangars during maintenance operations in the modern passenger and cargo aircraft sectors as well as the defence industry.


Project Application | Specification & Supply of ATEX Compliant HeatersStockists

Thorne & Derrick, The Experts in Equipment for Explosive Atmospheres, working in partnership with the MoD appointed M&E Design Consultancy have supplied ATEX Compliant Heaters to satisfy the Heating Clauses of their specification requirement to provide heaters suitable for installation in a Zone 2 hazardous area with Temperature Class 3 and IIB explosive gas atmospheres.

The project at a Royal Naval Air Station (RNAS) facility in the UK benefitted from the supply and installation of the LFH next-generation of ATEX & IECEx certified electric fan heaters for explosive atmospheres.

Manufactured by EXHEAT, a globally renowned manufacturer of electric process heating and control systems, the LFH model of Fixed Fan Heater combines superior efficiency with simple functionality to provide a ATEX Compliant heating solution for use in hazardous environments where the explosive atmosphere is classified as Zone 1/2 (IIB).

Design, Specify, Supply – DSEAR Compliant Heaters

Thorne & Derrick provided experienced design assistance to the Mechanical and Electrical Engineering contractor and design consultant for the selection of hazardous area space heaters to a new vehicle inspection and maintenance bay that was being constructed.

Thorne & Derrick were originally requested to submit a tender for Ex rated infrared heaters which had been specified at early design stage.

Thorne & Derrick Technical Sales Engineer reviewed the heating application, calculated heat losses and made a recommendation – due to the large open area the infra red heaters would have normally been selected to provide comfort heating for people working in the area. However, due to the hazardous area classification, gas group and T-class, T&D advised that the infra red heaters specified would not be compliant and pose a significant health and safety risk. From our large portfolio of ATEX certified heaters, T&D recommended the LFH heater based on its unrivalled air flow, temperature rise capability and compliance with the explosive atmosphere classification.

This was accepted by both the design consultant and M&E contractor.

T&D also offered advice to design consultant on possible use of ATEX high speed doors in the maintenance bay.

T&D advised that using high speed doors would help to reduce the overall heat loss and subsequent KW rating of any ATEX space heaters and therefore a reduction in energy consumption/costs.


LFH Flameproof Fixed Fan Heater

Hazardous Area Fan HEATERS

ATEX Certified | Up to 40kW

Zone 1 & Zone 2 (IIB) | T2 T3 & T4 Temperature Classes

EXHEAT LFH Fan Heater combines superior electrical heating efficiency with simple functionality to provide a next-generation heating solution for use in hazardous area environments where the explosive atmosphere is classified as Zone 1/2 (IIB) according to the ATEX Directive.

Certified to the new EN 80079-36 and EN 80079-37 standards for constructional safety, the EXHEAT LFH is supplied ready to ‘plug and play’, with the option of fitting a plug, or hard wiring to an isolator unit.

Incorporating a stainless steel casing for added toughness and durability, the LFH electric fan heater manufactured by EXHEAT is designed to operate in ambient temperatures of -40°C to +40°C, and uses a framework allowing for multiple mounting options on floors, walls and even ceilings in explosive atmospheres.

Depending on the heater model selected, inlet air temperatures can be increased by up to 46°C. Heaters are available up to 40kW output and provide class leading, energy efficient heating solutions for both onshore and offshore applications.

Temporary Heating Solution for Explosive Atmospheres

The EXHEAT LFH can also be manufactured and supplied as a temporary heating solution with options for anti-static castors, lifting handles, built in isolator and controls if required. This version can also be ducted front and rear to provide a versatile heating option for hazardous area locations.

DSEAR Compliant Heaters

Specifying Safe & Innovative Electrical Heating Systems for ATEX Compliance I DSEAR Compliant Heaters


Thorne & Derrick Logo

EXPERTS IN EQUIPMENT FOR EXPLOSIVE ATMOSPHERESExplosive Atmospheres

leaders in ATEX Innovation To The Hazardous Area Industries

Thorne & Derrick are leaders in the development and distribution of Product Innovations that deliver significant improvements to clients plant, people and operational safety in the explosive atmosphere industries.

Your proactive problem solvers experienced in succession planning for the replacement of obsolete, non-conformant and legacy equipment in hazardous areas.

Your first-choice provider of innovative and competitive solutions to ensure ATEX & IECEx Compliance for Hazardous Area Electrical, HVAC & Process Instrumentation Equipment to UK and international projects.

Control Panels | Plugs | Isolators | Enclosures & Junction Boxes | Lighting | Control Stations | Motor Starters | Trace Heating | Gas Detection | Flame Detection | Process Instrumentation | Process Heating | Ventilation Fans | Security Access Control 

Hazardous Area Electrical Equipment

Competitive Prices | Extensive Stocks | Technical Support | Express Delivery

Experts In Equipment for Explosive Atmospheres & Hazardous Area Locations

Further Information | Lock | Door | Heater | Fan

Trace Hating Cables And Heat Tracing Systems

Trace Heating | Heat Tracing Cables & Systems | Largest UK Stocks | Export Sales

Chocolate

Process Pipework Heating

Ever wondered how chocolate factories maintain their chocolate flowing smoothly and constantly so you can enjoy your favourite box or bar?

Chocolate must be kept fluid and at a constant temperature in pipework and vats during the entire production process.

Fluctuations in temperature during transport and processing have an immediate impact on the quality of the manufactured chocolate.

Chocolate is one of the most temperature sensitive products of all – to maintain quality and taste requires maintaining temperatures in a narrow range between 40 and 45°C.

Thorne & Derrick International supply heated hoses, trace heating and heating cables for pipelines to ensure optimum temperature maintenance is achieved and manufacturing losses are eliminated for the chocolate producer. We can design and supply electrical heat tracing systems for process temperature maintenance in commercial, industrial and hazardous area applications – call us.

winterisation products

Heating Cables | Pipework | Hoses | Drums | IBC


EXPERTS IN WINTERISATION SOLUTIONS FOR INDUSTRIAL & HAZARDOUS AREA ENVIRONMENTS

Heat Tracing I Frost Protection

Thorne & Derrick hold the largest UK stocks of frost protection & winterisation equipment to help keep your plant and personnel operational during the winter months.

Thorne & Derrick understand that prolonged periods of low ambient temperatures can bring operations to a standstill costing thousands of pounds in lost downtime.

Experts in heating solutions for use in industrial & explosive atmospheres, Thorne & Derrick have the knowledge & expertise to help clients prevent unnecessary down time this winter.

We can provide overnight delivery of Trace Heating Cables at the most competitive prices to guarantee frost protection of your pipelines and mechanical services.| Ask About Our Heat Trace Design Service.

💡 Contact us today and our skilled and friendly team can provide technical support as well as reliable, fit for purpose and compliant solutions to suit your exact requirements.

Trace Heating | Process Heating | Heating Jackets | Drum & IBC Heaters | Heated Hoses |Silicone Heating Mats

➡See our Winterisation blog TOP PICKS, including our most read articles about Trace Heating and the requirement for electrical heating products and systems to combat and mitigate Winter weather effects.

Winter heating 2021

Competitive Prices | Extensive Stocks | Technical Support | Express Delivery

Preferred Channel Partners for EXHEAT & Exclusive UK Stockists of The Bulldog, The World's First Portable ATEX & IECEx Certified Electric Heater

Preferred Channel Partners for EXHEAT & Exclusive UK Stockists of The Bulldog, The World’s First Portable ATEX & IECEx Certified Electric Heater (UKCA Pending)

EXHEAT Heaters | Distributed from Stock | International Delivery | Competitive Prices | Contact Us Today

EXHEAT | UKCA ATEX CERTIFIED

 HAZARDOUS AREA ELECTRICAL HEATING


The intent of this communication is to provide customer confidence and certainty about the future security of specification compliance for clients of EXHEAT Industrial Ltd and their Preferred Distributor, Thorne & Derrick.

From 1 January 2023 any products placed on the market for use in Explosive Atmospheres, in Great Britain (England, Wales and Scotland), must carry UKCA (UK Conformity Assessment) marking showing compliance to the new UKEx Scheme.

UKCA Conformity Assessment includes products that have previously required CE marking in compliance with the ATEX Directive. The conformity assessment and pertinent technical requirements used to assess and cover the compliance for UKCA markings are largely the same as they have been for CE marking to ATEX – consequently our manufacturing supply chain have been challenged with satisfying the requirements for UKCA conformity assessment to demonstrate and secure UKCA marking.

EXHEAT Bulldog Heater Portable ATEX Electric Fan Heaters

MFH Portable Fan Heater is the world’s first portable hazardous area fan heater. The EXHEAT Bulldog® combines efficient design with simple functionality to provide a portable heating solution for use in hazardous environments where the atmosphere is classified as Zone 1/2 (IIB) or Zone 21/22 (IIIC).

 

EXHEAT Industrial Ltd, the market leader in the manufacture of electric heating and controls for explosive atmospheres, are committed to establishing leadership on the legislative compliance of their products according to the requirements of UKCA.

EXHEAT Industrial Ltd have strategically devoted considerable resources in a concerted effort to ensure product compliance with UKCA Notified Body Approval to add to the already existing ATEX and IECEx certified products, making them triple certified – this will include their market-leading product ranges of: Air Warmers, Immersion Heaters, Temperature Controls & Thermostats, Water Heaters, Line Heaters and Fan Heaters.

Hazardous Area Heaters - Zone 1 Zone 2 ATEX

UKCA ATEX & IECEx Certified Electric Heaters for Explosive Atmospheres


UK Conformity Assessed marking is a certification mark that indicates conformity with the applicable requirements for products sold within Great Britain.

UKCA Resources from Thorne & Derrick

Experts in Equipment for Explosive Atmospheres


Distributors of UKCA ATEX & IECEx Electrical, Lighting, Heating & Ventilation Equipment

âž¡ Contact us to discuss your Electrical Heating, Lighting, Ventilation or Power requirements for safe and reliable use in hazardous areas and explosive atmospheres in accordance and compliance with UKCA certification requirements and ATEX/IECEx.

UKCA Support

Thorne & Derrick can assist with the specification and supply of UKCA “Ex” Accredited, Marked and Certified equipment for Explosive Atmospheres – Leaders In ATEX & IECEx Product Innovation | Supporting DSEAR Regulatory Compliance & COMAH Sites.

Blog

Thorne & Derrick & Raytec | Together Safely Lighting Hazardous Areas

Published 04 Jul 2019

Thorne & Derrick & Raytec | Together Safely Lighting Hazardous Areas

Press Release Date: 04.07.2019 uploaded by Chris Dodds (T&D Sales + Marketing Manager) Category: Stockist Distributor Agreement Announcement Thorne & Derrick International announce that they have signed a Preferred Distributor Agreement with Raytec, the world leading manufacturer of LED...

Read More

Associated manufacturers
Share this page
Share this page
X

Get a quote

Complete the form below to make an enquiry about products.

  • This field is for validation purposes and should be left unchanged.
  • Please enter your full name.
  • Please enter your contact telephone number.
  • Please enter your e-mail address.
  • Please select if you are enquiring about products for the UK or for export.